Tubing System Installation - Electrolux central vacuum systems Installation Manual

Central vacuum systems
Table of Contents

Advertisement

Tubing System Installation

Important notes for installation!
1) The 90° inlet elbow may be installed only together with the mounting
bracket and the inlet valve. Anywhere else in the tubing system, 90°
sweep elbows and 45° elbows should be used. (Fig. A and B)
mounting bracket
90° elbow
90°
sweep
elbow
A
2) Tubes are cut straight so that the cutting line is not slanted. Use a miter
saw if possible. Cut edges can be finished with a knife (to remove burrs).
3) For tubing joints, use suitable PVC glue to make the fittings secure and
tight. Apply a thin and even layer of glue only to the end of the tube – not
to the sleeve. This will prevent the glue from overflowing to the end face
of the tubing. Close the glue can carefully immediately after use and make
sure to have adequate ventilation during installation. Avoid inhaling glue
vapors. Insert the tube all the way into the sleeve while turning it at the
same time (Fig. C).
min. 3/4" (18 mm)
push the pipe completely into the fitting
C
4) The inlet is made through the fire wall according to Fig.figure E or by
using a 2" (50mm) diameter fire cuff (Fig. D). Check the inlet with a fire
authority.
fire stopping pipe
collars
D
pipe collars are attached
to the wall
protects the combustible
building material
wall
steel protective sleeve
E
min. 1/ 16" (2 mm)
B
min. 7 7/8"
(200 mm)
vacuum pipe
Begin the main tube installation with the farthest inlet valve and place the
tubes temporarily at first. Do not glue the joints yet until you have made
sure that the tubing routing is correct. The glue will dry quickly; therefore,
the joints have to be fitted right after applying the glue.
When measuring the tubes, take into account that the tube goes appro-
ximately 2/3" (18mm) into the sleeve and approximately 7/8" (20mm) into
the extension tube.
The tubing system can also be installed in a floor that will be concrete
casted later on (Fig. F). In such cases, the low-voltage cable must be
protected by a conduit pipe. The conduit pipe should be attached to the
vacuum tube or the casting net. For the vacuum tube, the routing channel
has to be 2" wide (51mm). The ends of the vacuum tubes and the con-
duit pipes should be plugged before concrete casting.
wire mesh
concrete
sand
F
vacuum pipe
Installation Examples
correct
incorrect
correct
incorrect
7
electrolux installation manual
2" (51 mm)
electrical tube
correct
incorrect

Advertisement

Table of Contents
loading

This manual is also suitable for:

Oxygen

Table of Contents