VENTING INSTRUCTION

- This cooking equipment shall be vented in accordance with requirements of Standard for
Ventilation Control and Fire Protection of Commercial Cooking Operations, NFPA 96.
- a min. 18 inch clearance from combustible material around the chimney shall be
maintained.
- The flue collar at the oven top shall be connect to UL Listed Factory Built Grease Duct
System/Building Heating Appliance Chimney System complying with Chapter 14 of NFPA
96. The collar must be locked with at least four
self-tapping screws
locking metal band to a
10 inches standard size chimney.
Picture 3: Smoke output
Picture 4: Air circulation into the oven and example of typical chimney installation schemes