Conversion From Natural Gas To Lpg; Minimum Flow Of Valved Cooking Hob Taps; Minimum Flow Of Non-Valved Cooking Hob Taps; Connecting To Lpg - John Lewis JLRC101 Instruction Manual

Mixed fuel range cooker
Table of Contents

Advertisement

Conversion from Natural Gas to LPG

If the cooking appliance is set up for a different type of gas
than that available, its injectors must be replaced, the
minimum flow regulated. In order to replace the injectors
in the cooking hob, it is necessary to carry out the
following operations:
Fig. A
• remove the pan supports;
• remove the burners and burner caps (Fig. A);
• take out the injector (Fig. B) and replace it with one
suitable for the new type of gas (see "General injectors
table");
• replace the gas label (on the rear of the appliance) with
the new one provided with the injectors kit;
• refit all parts by following the disassembly instructions in
reverse order and taking care to position the burner cap
correctly on the burner.
Minimum flow of valved cooking
hob taps
• Switch on the burner and turn the control knob towards
the minimum flow position
• remove the knob;
• using a screwdriver, adjust the internal screw Z until the
correct low flame is obtained;
• refit the knob.

General injectors table

TYPE OF GAS
NATURAL
GAS
G20 (E)
LPG
BUTANE
PROPANE
G30/G31
* Position A: front left, position D: centre rear (see also "Description of the cooktop").
Fig. B
;
mBar
INJECTOR NO.
INJECTOR
BY-PASS
115
44 GAP
97
34 GAP
20
72
27 GAP
128
60 GAP
128
60 GAP
85
44 GAP
65
34 GAP
28-30/37
50
27 GAP
93
60 GAP
93
60 GAP
Minimum flow of non-valved
cooking hob taps
• Switch on the burner and turn the control knob towards
the minimum flow position
• remove the knob;
• insert a small screwdriver into the rod of the tap and
adjust the internal screw Z until the correct low flame is
obtained;
• refit the knob.
Unscrew the adjustment screw Z to increase
the flow, or tighten it to reduce the flow. The
adjustment is correct when the low flame
measures approximately 3 or 4 mm. When
changing quickly from maximum to
minimum flow and vice versa make sure that
the flame does not go out.

Connecting to LPG

Use a pressure regulator and connect to the cylinder in
compliance with the guidelines set out in standards
regulations in force.
L.P.G. cookers MUST NOT be installed
below ground level i.e. in a basement or
aboard any boat, yacht or other vessel.
BURNERS
POWER Watts
POSITION TYPE
MAX.
RAPID
3000
SEMI-RAPID
1750
SIMMER
1000
TRIPLE RING (A)*
3300
TRIPLE RING (D)*
3300
RAPID
3000
SEMI-RAPID
1750
SIMMER
1000
TRIPLE RING (A)*
3300
TRIPLE RING (D)*
3300
11
;
MAX.
CONSUMPTION
MIN.
750
286 l/h
440
167 l/h
300
95 l/h
1500
314 l/h
1500
314 l/h
750
219 g/h
440
128 g/h
300
73 g/h
1500
240 g/h
1500
240 g/h