Technical Specification; Installation; Electrical Connection - John Lewis JLBIUCL 01 Instruction Manual

Built-in refrigerator
Table of Contents

Advertisement

Installation

It is dangerous to alter the specifications or
attempt to modify this product in any way.
Care must be taken to ensure that the
appliance does not stand on the electrical
supply cable.
Technical Data
Dimensions of recess
Height
Width
Depth
Dimensions of the appliance cavity
Height
Width
Depth
Fridge Gross capacity
Fridge Net capacity

Electrical connection

Any electrical work required to install this appliance
should be carried out by a qualified electrician or
competent person.
WARNING:THIS APPLIANCE MUST BE
EARTHED.
The manufacturer declines any liability should this
safety measure not be observed.
If the plug that is fitted to your appliance is not suitable
for your socket outlet, it must be cut off and the
appropriate plug fitted.
Remove the fuse from the cut off plug.
The cut off plug should then be disposed of to prevent
the hazard of shocks in case it should be plugged into a
13amp socket in another part of your home.
Important
The wires in the mains lead are coloured in accordance
with the following code:
Green and Yellow
- Earth
Blue
Brown
If you fit your own plug, the colours of the wires in the
mains lead of your appliance may not correspond with
the markings identifying the terminals in your plug,
proceed as follows:
6
820 mm
600 mm
550 mm
815 mm
596 mm
550 mm
142 litres
140 litres
- Neutral
- Live
Any electrical work required to install this
appliance should be carried out by a qualified
electrician or competent person.
Heating elements rating
Supply voltage (50 Hz)
Connected load,
Fridge light
1. Connect the Green and Yellow (earth) wire to the
terminal in the plug which is marked with the letter
«E» or the earth symbol
yellow.
2. Connect the blue (neutral) wire to the terminal in the
plug which is marked with the letter «N» or coloured
black.
3. Connect the brown (live) wire to the terminal in the
plug which is marked with the letter «L» or coloured
red.
4. Upon completion there must be no cut, or stray
strands of wire present and the cord clamp must be
secure over the outer sheath.The plug moulded onto
the lead incorporates a fuse. For replacement, use a
13amp BSI362 fuse. Only ASTA or BSI approved fuses
should be used.
The plug must not be used if the fuse cover/carrier is
lost.The cover/carrier is indicated by the coloured insert
at the base of the plug.
A replacement cover/carrier must be obtained from your
local Service Force Centre.
220-240 V
70 W
15 W
or coloured green and