5.

SPARK ARRESTER MAINTENANCE

If the generator has been running, the muffler will be very hot.
Allow it to cool before proceeding.
The spark arrester must be serviced every 100 hours to maintain its
efficiency.
1.
Remove the four 6 mm cap nuts, and remove the rear cover.
2.
Remove the four 6 mm bolts and the earth washer (C type only), and
remove the upper muffler protector.
UPPER MUFFLER
PROTECTOR
6 mm CAP
NUTS
3.
Remove the four 8 mm bolts, and remove the rear handle pipe.
4.
Remove the four 6 mm bolts and the earth washer (C type only), and
remove the rear under plate.
5.
Remove the lower muffler protector.
LOWER MUFFLER PROTECTOR
REAR HANDLE PIPE
6 mm BOLTS
48
6 mm BOLTS
REAR COVER
8 mm BOLTS
REAR UNDER PLATE
EARTH WASHER
(C type only)
EARTH WASHER
(C type only)