Flue terminal position

• If the appliance is to be installed in a
room containing a bath or shower, any
electrical switch or control
utilising mains electricity must be so
situated that it cannot be touched by a
person using the bath or shower.
Attention is drawn to the
requirements of BS 7671 (the
current I.E.E Wiring Regulations) and in
Scotland the electrical provisions of
the Building Regulations
applicable in Scotland.
Flue termination position
Horizontal flue system
Position
A
Directly below an openable window, air vent or any other ventilation opening
B
Below a gutter, drain or soil pipe
4/9/07
7:27 pm
Page 13
• A compartment used to enclose the
appliance must be designed and
constructed specifically for this
purpose. An existing cupboard or
compartment may be used provided it
is modified accordingly. BS 7698:2000
gives details of the essential features
of cupboard / compartment design,
including airing cupboards.
• Where installation will be in an unusual
location, special procedures may be
necessary. BS 6798 gives detailed
guidance on this aspect.
Minimum Spacing
300mm
75mm
13