Setting The Economy Temp (Tr2 Connected); Manual Operating Mode (Tr2 Not Connected); Hot Water; Info - Benchmark RD 532i Installation And Servicing Instructions

Wall mounted condensing boiler for central heating and mains fed domestic hot water
Table of Contents

Advertisement

6.5.2
Setting the Economy temperature (if TR2
is connected)
This option allows you to set the room temperature for
Economy mode (Off (Economy)).
This function is only active if:
• Automatic mode or Economy mode is set on the TR2
room thermostat.
B From the main menu, select Heating and then from
the first submenu, select Set Economy temp..
B Use the
or
button to set a temperature
between 5 and 30 °C.
6.5.3
Manual operating mode (if TR2 is not con-
nected)
For selecting an operating mode that is different from
the one set in the heating programme (Automatic
mode).
• You can choose between Automatic, Constant on
(comfort) and Constant off (economy).
• The manually selected operating mode starts imme-
diately.
• Constant off (economy) and Constant on (comfort)
are automatically reset at 00.00 (midnight).
• To cancel the manually selected operating mode:
– select the relevant menu and then press the
button,
– or select a different operating mode,
– or set Holiday.
B From the main menu select Heating and then from
the first submenu Manual select required mode.
6.6

Hot water

General description
• Combi models only: The basic settings provide a
straightforward timer programme:
enabling Hot Water pre-heat from 5:00am
disabling Hot Water preheat from 10:00pm.
The ECO button must not be lit.
6 720 611 447 GB (03.11)
6.7
i Info
B Select Info from the main menu.
You can view the following information:
Display text
Room tempera-
ture
(if TR 2 connected)
Required room
temperature
(if TR 2 connected)
Operating mode
(if TR 2 connected)
Max. flow temp.
Actual flow temp.
Required flow
temp.
C
Max HW temp.
Required HW
temp.
Actual HW temp.
Storage Tank
charge released
or blocked
Storage Tank
charge on or off
or Storage Tank
charge
afterrunning
Boiler operat.
mode
winter/ summer
Burner on/off
Pump on/off
Text Display
Description
Current temperature in the
room where TR 2 is installed
Required temperature in
room where TR 2 is installed
E. g. Heating, Economy in
Automatic mode
or
Economy, Heating, Frost
protection in manual mode
Maximum CH flow tempera-
ture set on the temperature
control for CH flow
Actual CH flow temperature
Required CH flow tempera-
ture
Maximum permissible hot
water outflow temperature
Required hot water temper-
ature
Actual hot water outflow
temperature
Shows, if hot water is
released or blocked
Shows, if hot water is on or
off, or if the pump for the
Storage Tank afterrunning is
on
Indicates which mode the
CH flow temperature control
is set to
Indicates whether the burner
is alight or not
Indicates whether the inte-
gral pump is switched on or
off
29