ITEM
Type
Material
Motor Type
Input Power
Output Power
Fan
Fan Speed
Fin Material
Fin Type
Heat Exchanger
Row x Stage x FPI
Size (W x H x L)
Material
Air Filter
Type
1. Cooling capacities are based on indoor temperature of 27 C D.B. (80.6 F D.B.), 19.0 C W.B. (66.2 F W.B.) and outdoor air
temperature of 35 C D.B. (95 F D.B.), 24 C W.B. (75.2 F W.B.)
2. Heating capacities are based on indoor temperature of 20 C D.B. (68 F D.B.) and outdoor air temperature of 7 C D.B. (44.6 F
D.B.), 6 C W.B. (42.8 F W.B.)
Item
Power Source (Phase, Voltage, Cycle)
Input Power
Starting Current
Running Current
Maximum current
Power Factor
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Number of core
Power Cord
Length
Thermostat
Protection Device
Note
• Specifications are subject to change without notice for further improvement.
UNIT
W
W
QLo (Cool/Heat)
rpm
Lo (Cool/Heat)
rpm
Me (Cool/Heat)
rpm
Hi (Cool/Heat)
rpm
SHi (Cool/Heat)
rpm
mm
Unit
ø
V
Hz
W
A
A
A
%
m
6
INDOOR UNIT
Cross-Flow Fan
ASG20K1
Transistor (8-pole)
30
680 / 780
780 / 850
1010 / 1085
1240 / 1320
1310 /1390
Aluminium (Pre Coat)
Slit Fin
2 x 15 x 17
610 x 315 x 25.4
Polypropelene
One-Touch
Single
230
50
Cooling; 470 (170 ~ 580)
Heating; 635 (160 ~ 1020)
3.0
Cooling; 2.2
Heating; 3.0
4.8
Cooling; 93
Heating; 92
Electronic Control
Electronic Control
OUTDOOR UNIT
Propeller Fan
PP
Induction (6-pole)
62
25
750 / -
Aluminium
Corrugated Fin
2 x 24 x 17
36.4 x 504 x 713
684