Panasonic CS-E7HKEW Service Manual page 12

Air conditioner
Hide thumbs Also See for CS-E7HKEW:
Table of Contents

Advertisement

ITEM
Type
Material
Motor Type
Input Power
Output Power
Fan
Fan Speed
Fin Material
Fin Type
Heat Exchanger
Row x Stage x FPI
Size (W x H x L)
Material
Air Filter
Type
1. Cooling capacities are based on indoor temperature of 27 C D.B. (80.6 F D.B.), 19.0 C W.B. (66.2 F W.B.) and outdoor air
temperature of 35 C D.B. (95 F D.B.), 24 C W.B. (75.2 F W.B.)
2. Heating capacities are based on indoor temperature of 20 C D.B. (68 F D.B.) and outdoor air temperature of 7 C D.B. (44.6 F
D.B.), 6 C W.B. (42.8 F W.B.)
Item
Power Source (Phase, Voltage, Cycle)
Input Power
Starting Current
Running Current
Maximum current
Power Factor
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Number of core
Power Cord
Length
Thermostat
Protection Device
Note
• Specifications are subject to change without notice for further improvement.
UNIT
W
W
QLo (Cool/Heat)
rpm
Lo (Cool/Heat)
rpm
Me (Cool/Heat)
rpm
Hi (Cool/Heat)
rpm
SHi (Cool/Heat)
rpm
mm
Unit
ø
V
Hz
W
A
A
A
%
m
12
INDOOR UNIT
Cross-Flow Fan
ASG20K1
Transistor (8-pole)
30
850 / 1160
990 / 1230
1245 / 1390
1500 / 1550
1560 / 1570
Aluminium (Pre Coat)
Slit Fin
2 x 15 x 21
610 x 315 x 25.4
Polypropelene
One-Touch
Single
230
50
Cooling; 1.37k (215 ~ 1.60k)
Heating; 1.57k (245 ~ 2.25k)
7.1
Cooling; 6.3
Heating; 7.1
10.2
Cooling; 95
Heating; 96
Electronic Control
Electronic Control
OUTDOOR UNIT
Propeller Fan
PP
Transistor (8-pole)
40
660 / 640
Aluminium
Corrugated Fin
1 x 28 x 18
22 x 711 x 835

Hide quick links:

Advertisement

Table of Contents
loading