In Case Of Doubt; Error Displays; Troubleshooting - Omron KaradaScan HBF-375 Instruction Manual

Body composition monitor with scale
Hide thumbs Also See for KaradaScan HBF-375:
Table of Contents

Advertisement

In Case of Doubt

■ Error Displays

Error Display
Your palms or soles are not in firm
contact with the electrodes.
The posture for measurement is
wrong or the palms or soles are not in
firm contact with the electrodes.
The palms or soles are too dry.
Abnormal operation
You stepped on the unit before the
display indicated "0.0 kg".
You moved the main unit before the
display indicated "0.0 kg".
You moved your body during
measuring.
When measuring, body weight
measuring range is exceeded.

■ Troubleshooting

Problem
"0.0 kg" is displayed even when you step
onto the unit, or the weight value barely
increases.
The value of body weight is displayed
abnormally high or low.
The value of body weight is displayed
high
Measurement results is abnormally high
or low
Measurement results achieved each time
is great different from each other
"
" is displayed for some
of the results.
Nothing is displayed when the power is
turned on.
27
Cause
Press your palms or soles firmly to the electrodes, then
measure. (
Measure without moving the hands or soles.
(
Moisten the palms or soles with a wet towel, and then
repeat measurement.
Insert the batteries again and repeat measurement.
Consult OMRON authorised dealer.
Reconnect the power and step onto the main unit until
the display indicated "0.0 kg".
Reconnect the power and do not move the main unit
until the display indicates "0.0 kg".
Do not move your body during measuring.
Body weight of 135 kg or over is out of the measuring
range of this unit. You cannot use this unit.
Cause
You stepped onto the unit before "0.0 kg"
was displayed.
Display unit is taken out before "0.0 kg" is
displayed.
Measuring posture is incorrect
Is the unit placed on a carpet or other
soft flooring?
Is the floor surface is uneven?
The soles of your feet, or whole body are
cold, causing poor blood circulation.
The electrodes are extremely cold.
Palms and soles are too dry.
Your height, gender and birth is not correctly set.
This unit cannot measure body composition because of its measurement range, even
if the height, gender and birth date settings are correct.
Batteries are not inserted.
The polarities of batteries are not aligned
correctly.
The batteries are worn out.
Cord connecting the main unit and the
display unit is damaged.
Correction
page 17 and 18)
page 17 and 18)
Correction
Wait until "0.0 kg" is displayed before
stepping onto the unit.
Wait until "0.0 kg" is displayed before
taking out display unit.
Take a measurement with correct
posture (
page 17 and 18)
Place the unit on a hard and level floor.
Warm yourself up, and then take a
measurement once you feel your
circulation is back to normal.
Place the unit in a warm room for a few
minutes, and then take a measurement
when the electrodes no longer feel cold.
Slightly moisten your palms and soles
with a damp towel and try again.
Insert the batteries. (
Insert the batteries in correct alignment.
(
page 8)
Replace all four batteries with new ones.
(
page 8)
Consult OMRON authorised dealer.
page 8)