Omron VIVA Instruction Manual

Omron VIVA Instruction Manual

Body composition monitor
Hide thumbs Also See for VIVA:

Advertisement

Body Composition Monitor
• Instruction Manual
• Gebrauchsanweisung
• Mode d'emploi
• Manual de instrucciones
• Manuale di istruzioni
• Gebruiksaanwijzing
Thank you for purchasing the OMRON Body Composition Monitor.
Before using this unit, please be sure to read this Instruction Manual carefully to
understand the safe and proper use.
Please store this Instruction Manual carefully for future reference.
VIVA (HBF-222T-EBK)
IM-HBF-222T-E-07-05/2021
3135909-5F
EN
DE
FR
ES
IT
NL
RU
TR
AR

Advertisement

Table of Contents
loading

Summary of Contents for Omron VIVA

  • Page 1 • Manual de instrucciones • Manuale di istruzioni • Gebruiksaanwijzing Thank you for purchasing the OMRON Body Composition Monitor. Before using this unit, please be sure to read this Instruction Manual carefully to understand the safe and proper use. Please store this Instruction Manual carefully for future reference.
  • Page 2: Table Of Contents

    VIVA Body Composition Monitor Intended Use Thank you for purchasing this OMRON Body Composition Monitor. This unit is intended for measuring and displaying the following body composition parameters. - Body Weight - Body Fat (in %) - Visceral Fat (up to 30 levels)
  • Page 3: Before Using The Unit

    Before using the unit Notes on Safety Danger: Improper use may cause danger resulting in death or serious injury. Warning: Improper use may result in possible death or serious injury. Caution: Improper use may result in injury or property damage. Danger: •...
  • Page 4 • • Remove the batteries from this unit when you are not going to use it for a long period of time (approximately three months or more). • • Do not use new and worn batteries together. • disease, you may cause infection to other people. •...
  • Page 5: Know Your Unit

    Before using the unit 1. Know Your Unit Main Unit Display Foot Electrodes Foot Electrodes Feet (×4) ON/OFF Button • Press this button to turn on the power. • Bluetooth Button • Press this button to transfer the data manually. •...
  • Page 6: Insert And Replace The Batteries

    When the batteries are replaced, you need to reset the measurement unit, date and time. (Refer to Section 4.) • If you have already paired with the “OMRON connect” app, press the button to communicate with this app, then the date and time will be set automatically.
  • Page 7: Pair The Unit With Your Smart Device

    • One smart device manages the data of one user. • If an app other than “OMRON connect” is used, data might not be transferred correctly. • Please read the utilization method and usage instruction within the app for details.
  • Page 8: Set The Measurement Unit, Date And Time

    Before using the unit 4. Set the Measurement Unit, Date and Time time or after replacing the batteries. • Date and time can be set from “OMRON connect” app as well. Press the button to turn on the power. “kg&cm” blinks on the display.
  • Page 9: Register The Personal Data

    For the measurement of body composition, it is necessary to register your personal data (birth date, gender, height). The registered data can be stored for up to 4 persons. • The personal data can be registered from “OMRON connect” app as well. Press the button to turn on the power.
  • Page 10: Operating Instructions

    Step onto the unit to take a measurement when “0.0 kg” is displayed. The data of body weight and body composition are recorded in the unit to support automatic recognition. After a while, the measurement results are indicated as follows. The personal data registration is completed.
  • Page 11: About The "0 Kg Correction" (Caution For Storing)

    6.2 About the “0 kg correction” (Caution for storing) The unit regularly corrects accuracy automatically when it is not in use. • If the unit is placed as shown below this accuracy correction function does not work, implement the “0 kg correction” before taking the measurement. The unit is leaning against The unit is placed The unit is placed on...
  • Page 12 When you step onto the unit, the power automatically turns on. When personal number and measurement results are displayed, the measurement is completed. ■ If your personal number is correct… Press the number. disappears. blinking, the results are recorded on the unit as the measurement value linked to the displayed personal number.
  • Page 13: Use The Memory Function

    Visceral Fat Level PERCENTAGE Classification Skeletal Muscle Percentage Classification Press the Use the Memory Function 8. View the Measurement Results on Your results. device. Note • The “OMRON connect” app must be installed on your smart device. (Refer to Section 3.)
  • Page 14: When Necessary

    When necessary 9. Select Your Personal Number and Take a Measurement If your personal number is not recognized frequently, you can select your personal number and take the measurement as follows. Press the button to turn on the power. The power turns on. Personal number “1” blinks. Select your personal number.
  • Page 15: Guest Mode (Unrecorded Mode)

    When necessary 10. Guest Mode (Unrecorded Mode) When this mode is used, your measurement results will not be recorded. Press the button to turn on the power. The power turns on. Personal number “1” blinks. ”. Select “GUEST” with the button, and then press the Enter personal data.
  • Page 16: Measure Weight Only

    Start Measurement when “0.0 kg” is displayed. Step onto the unit. Check the measurement results. The results display rotates automatically. Press the When necessary 11. Measure Weight Only When this mode is used, your measurement result will not be recorded. Press the button to turn on the power.
  • Page 17: Change Or Delete Your Personal Data

    When necessary 12. Change or Delete Your Personal Data Press the button to turn on the power. The power turns on. Personal number “1” blinks. Select your personal number Press the button to select the personal number. When the birth date ( ) is displayed, Your personal data is not registered in your personal number.
  • Page 18: Delete The Communication Setting

    When necessary 13. Delete the Communication Setting If you want to stop the use of the “OMRON connect” app or delete the communication settings from your smart device, please operate as follows. All the communication settings recorded in the unit will be deleted.
  • Page 19: Troubleshooting

    If this error Device error. continues to display, consult the OMRON service representative. Communication failure. error is displayed again, contact the OMRON service representative. You moved during a Stand still during a measurement. measurement.
  • Page 20 Problem Cause Correction Transfer the measurement results to 24-29 sets of measurements “OMRON connect” app, then the symbol results have been stored. will disappear. blinks If the number exceeds 30, the oldest results are deleted.Transfer the 30 sets of measurements measurement results to “OMRON...
  • Page 21 The button is wet or respond. contaminated. a measurement. You pressed two or more Press one button at a time. buttons simultaneously. Refer to “About the Power OFF Function”. (Refer to Section 2.) Failure to send data Refer to “Help” in “OMRON connect” app.
  • Page 22: Technical Data

    Product Category Body Composition Analyzers Product Description Body Composition Monitor Model (code) VIVA (HBF-222T-EBK) Display* Body Weight: 2.0 to 150.0 kg with an increment of 0.1 kg (4.4 to 330.0 lb with an increment of 0.2 lb) (0 st 4.4 lb to 23 st 8.0 lb with an increment of 0.2 lb) Body Fat 5.0 to 60.0% with an increment of 0.1%...
  • Page 23 Important information regarding Electro Magnetic Compatibility (EMC) Electro Magnetic Compatibility (EMC) standard. Further documentation in accordance with this EMC standard is available at OMRON HEALTHCARE EUROPE at the address mentioned in this instruction manual or at www.omron-healthcare.com. Refer to the EMC information for HBF-222T-...
  • Page 24 Warranty OMRON HEALTHCARE EUROPE B.V. guarantees this product for 3 years after date of purchase. The guarantee does not cover battery, packaging and/or damages of any kind due to misusage (such as dropping or physical misuse) caused by the user. Claimed products will only be replaced when returned together with the original invoice / cash ticket.
  • Page 25: Information On Body Composition

    Body fat is tissue that has little electric conductivity. The VIVA sends an extremely weak electrical current of 50 kHz and less than 500 A through your body to determine the amount of fat tissue. This weak electrical current is not felt while operating the VIVA.
  • Page 26 Body fat percentage refers to the amount of body fat mass in regards to the total body weight expressed as a percentage. Body fat percentage (%) = {Body fat mass (kg) / Body weight (kg)} × 100 The VIVA uses the BI method to estimate your body fat percentage. fat. Visceral fat = fat surrounding internal organs...
  • Page 27: Measurement Results Interpretation Diagrams

    Information on body composition 18. Measurement Results Interpretation Diagrams Interpreting the Body Fat Percentage Result -(Low) 0(Normal) +(High) ++(Very High) < 16.1% 16.1 - 32.2% 32.3 - 35.2% 35.3% < 16.3% 16.3 - 33.1% 33.2 - 36.0% 36.1% < 16.4% 16.4 - 33.5% 33.6 - 36.3% 36.4%...
  • Page 28 Interpreting the Skeletal Muscle Percentage Result -(Low) 0(Normal) +(High) ++(Very High) 18 - 39 < 24.3% 24.3 - 30.3% 30.4 - 35.3% 35.4% Female 40 - 59 < 24.1% 24.1 - 30.1% 30.2 - 35.1% 35.2% 60 - 80 < 23.9% 23.9 - 29.9% 30.0 - 34.9% 35.0%...
  • Page 30 Manufacturer OMRON HEALTHCARE Co., Ltd. 53, Kunotsubo, Terado-cho, Muko, KYOTO, 617-0002 JAPAN OMRON HEALTHCARE EUROPE B.V. EU-representative Scorpius 33, 2132 LR Hoofddorp, THE NETHERLANDS www.omron-healthcare.com Krell Precision (Yangzhou) Co., Ltd. Production facility No.28, Xingyang Road, Economic Development Zone, Yangzhou Jiangsu 225009, China OMRON HEALTHCARE UK LTD.

This manual is also suitable for:

Hbf-222t-ebk

Table of Contents