Omron VIVA Instruction Manual

Omron VIVA Instruction Manual

Body composition monitor
Hide thumbs Also See for VIVA:

Advertisement

Body Composition Monitor
Thank you for purchasing the OMRON Body Composition Monitor.
Before using this unit, please be sure to read this Instruction Manual carefully to
understand the safe and proper use.
Please store this Instruction Manual carefully for future reference.
VIVA (HBF-222T-EBK)
IM-HBF-222T-E-04-01/2018
3135909-5D
EN
DE
FR
ES
IT
NL
RU
TR
AR

Advertisement

Table of Contents
loading

Summary of Contents for Omron VIVA

  • Page 1 Body Composition Monitor VIVA (HBF-222T-EBK) Thank you for purchasing the OMRON Body Composition Monitor. Before using this unit, please be sure to read this Instruction Manual carefully to understand the safe and proper use. Please store this Instruction Manual carefully for future reference.
  • Page 2: Table Of Contents

    VIVA Body Composition Monitor Thank you for purchasing this OMRON Body Composition Monitor. This unit is intended for measuring and displaying the following body composition parameters. - Body Weight - Body Fat (in %) - Visceral Fat (up to 30 levels)
  • Page 3 Before using the unit Improper use may cause danger resulting in death or serious injury. Improper use may result in possible death or serious injury. Improper use may result in injury or property damage. (1) Medical electronic implants such as pacemakers. (3) Portable electronic medical devices such as an electrocardiograph.
  • Page 4 Remove the batteries from this unit when you are not going to use it for a long period of time (approximately three months or more). Do not use different types of batteries together. Do not use new and worn batteries together. Always wash your feet before using the unit.
  • Page 5: Pair The Unit With Your Smart Device

    Before using the unit Display Foot Electrodes Foot Electrodes Feet (×4) Press this button to turn on the power. Press this button (2 seconds or longer) to turn off the power. Press this button to transfer the data manually. Press this button (2 seconds or longer) to pair the unit with your smart device. This button is also usable when the power is off.
  • Page 6 Disposal of used batteries should be carried out in accordance with the national regulations for the disposal of batteries. If you have already paired with the “OMRON connect” app, press the button to communicate with this app, then the date and time will be set automatically.
  • Page 7 Menu>Device>Add Device NOTES One smart device manages the data of one user. If an app other than “OMRON connect” is used, data might not be transferred correctly. Please read the utilization method and usage instruction within the app for details.
  • Page 8: Set The Measurement Unit, Date And Time

    Before using the unit time or after replacing the batteries. Date and time can be set from “OMRON connect” app as well. “kg&cm” blinks on the display. Press the button to adjust and press the The default measurement unit is “kg & cm”.
  • Page 9 For the measurement of body composition, it is necessary to register your personal data (birth date, gender, height). The registered data can be stored for up to 4 persons. The personal data can be registered from “OMRON connect” app as well. The power turns on. Personal number “1” blinks. Birth date ( ) is displayed.
  • Page 10: Take A Measurement

    The data of body weight and body composition are recorded in the unit to support automatic recognition. After a while, the measurement results are indicated as follows. The personal data registration is completed. To add new personal data, start from the “Step 1”. Operating instructions Step onto the unit with your bare feet.
  • Page 11: Operating Instructions

    The unit regularly corrects accuracy automatically when it is not in use. If the unit is placed as shown below this accuracy correction function does not work, implement the “0 kg correction” before taking the measurement. The unit is leaning against The unit is placed The unit is placed on An object is placed...
  • Page 12 When you step onto the unit, the power automatically turns on. Step off the unit. ■ Press the number. disappears. Even if you turn off the power with blinking, the results are recorded on the unit as the measurement value linked to the displayed personal number. ■...
  • Page 13 Visceral Fat Level PERCENTAGE Classification Skeletal Muscle Percentage Classification The power turns off if the unit is not used for 3 minutes. Use the Memory Function device. The “OMRON connect” app must be installed on your smart device. (Refer to Section 3.)
  • Page 14 When necessary If your personal number is not recognized frequently, you can select your personal number and take the measurement as follows. The power turns on. Personal number “1” blinks. Select your personal number with the button. Register your personal data. (Refer to Section 5.) “0.0 kg”...
  • Page 15 When necessary When this mode is used, your measurement results will not be recorded. The power turns on. Personal number “1” blinks. Select “GUEST” with the button, and then press the 3.1 Set the birth date Press the button to set the birth date and press the button to Year During setting the year and date, hold down the...
  • Page 16 Step onto the unit. The results display rotates automatically. The power turns off if the unit is not used for 3 minutes. When necessary When this mode is used, your measurement result will not be recorded. The power turns on. Personal number “1” blinks. Select “...
  • Page 17 When necessary The power turns on. Personal number “1” blinks. Press the button to select the personal number. When the birth date ( ) is displayed, Your personal data is not registered in your personal number. Register your personal data. (Refer to Section 5.) “0.0 kg”...
  • Page 18: Delete The Communication Setting

    When necessary If you want to stop the use of the “OMRON connect” app or delete the communication settings from your smart device, please operate as follows. All the communication settings recorded in the unit will be deleted. “ ” and the Bluetooth symbol blink.
  • Page 19 OMRON service representative. Turn off the power and try to communicate again. If this Communication failure. error is displayed again, contact the OMRON service representative. You moved during a Stand still during a measurement. measurement.
  • Page 20 Transfer the measurement results to 24-29 sets of measurements “OMRON connect” app, then the symbol results have been stored. will disappear. blinks If the number exceeds 30, the oldest results are deleted.Transfer the 30 sets of measurements measurement results to “OMRON results have been stored.
  • Page 21 Wipe off the water or stain before taking contaminated. a measurement. You pressed two or more Press one button at a time. buttons simultaneously. Refer to “About the Power OFF Function”. (Refer to Section 2.) Refer to “Help” in “OMRON connect” app.
  • Page 22 When necessary Body Composition Monitor VIVA (HBF-222T-EBK) 2.0 to 150.0 kg with an increment of 0.1 kg (4.4 to 330.0 lb with an increment of 0.2 lb) (0 st 4.4 lb to 23 st 8.0 lb with an increment of 0.2 lb) 5.0 to 60.0% with an increment of 0.1%...
  • Page 23 Android, the Google Play logo are trademarks of Google Inc. Electro Magnetic Compatibility (EMC) standard. Further documentation in accordance with this EMC standard is available at OMRON HEALTHCARE EUROPE at the address mentioned in this instruction manual or at www.omron-healthcare.com. Refer to the EMC information for HBF-222T-...
  • Page 24 OMRON HEALTHCARE EUROPE B.V. guarantees this product for 3 years after date of purchase. The guarantee does not cover battery, packaging and/or damages of any kind due to misusage (such as dropping or physical misuse) caused by the user. Claimed products will only be replaced when returned together with the original invoice / cash ticket.
  • Page 25: Information On Body Composition

    Body fat is tissue that has little electric conductivity. The VIVA sends an extremely weak electrical current of 50 kHz and less than 500 A through your body to determine the amount of fat tissue. This weak electrical current is not felt while operating the VIVA.
  • Page 26 Body fat percentage refers to the amount of body fat mass in regards to the total body weight expressed as a percentage. The VIVA uses the BI method to estimate your body fat percentage. fat. Visceral fat = fat surrounding internal organs...
  • Page 27 Information on body composition Interpreting the Body Fat Percentage Result < 16.1% 16.1 - 32.2% 32.3 - 35.2% 35.3% < 16.3% 16.3 - 33.1% 33.2 - 36.0% 36.1% < 16.4% 16.4 - 33.5% 33.6 - 36.3% 36.4% < 16.4% 16.4 - 33.8% 33.9 - 36.5% 36.6% <...
  • Page 28 Interpreting the Skeletal Muscle Percentage Result 18 - 39 < 24.3% 24.3 - 30.3% 30.4 - 35.3% 35.4% 40 - 59 < 24.1% 24.1 - 30.1% 30.2 - 35.1% 35.2% 60 - 80 < 23.9% 23.9 - 29.9% 30.0 - 34.9% 35.0% 18 - 39 <...
  • Page 30 Manufacturer OMRON HEALTHCARE Co., Ltd. 53, Kunotsubo, Terado-cho, Muko, KYOTO, 617-0002 JAPAN OMRON HEALTHCARE EUROPE B.V. EU-representative Scorpius 33, 2132 LR Hoofddorp, THE NETHERLANDS www.omron-healthcare.com Krell Precision (Yangzhou) Co., Ltd. Production facility No.28, Xingyang Road, Economic Development Zone, Yangzhou Jiangsu 225009, China OMRON HEALTHCARE UK LTD.