FOR YOUR SAFETY
If you smell gas:
1. Open windows.
2. Don't touch electrical switches.
3. Extinguish any open fl ame.
4. Immediately call your gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other
fl ammable vapors and liquids in the
vicinity of this or any other appliance.
!
Improper installation, adjustment, altera-
tion, service or maintenance can cause
injury or property damage. Refer to this
manual. For assistance or additional infor-
mation consult a qualifi ed installer, serv-
ice agency or the gas supplier.
USA
Service Offi ce
Dometic Corporation
2320 Industrial Pkwy.
Elkhart, IN 46516
Phone: 574-294-2511
825125500
(French 825125550)
©2006 Dometic Corporation
LaGrange, IN 46761
®
WARNING
2320 Industrial Parkway Elkhart, IN 46515
For Service Center Assistance
INSTALLATION
MANUAL
REFRIGERATOR FOR LP-GAS
& ELECTRIC OPERATION
POUR VOTRE SÉCURITÉ
Si vous sentez une odeur de gaz:
1. Ouvrez les fenêtres.
2. Ne touchez à aucun interrupteur.
3. Éteignez toute fl amme nue.
4. Avertissez immédiatement votre
fournisseur de gaz.
POUR VOTRE SÉCURITÉ
Ne pas entreposer ni utiliser de l'essence
ni d'autres vapeurs ou liquides infl amma-
bles à proximité de cet appareil ou de tout
autre appareil.
Une installation, un réglage, une modifi -
cation, une réparation ou un entretien non
conforme aux normes peut entraîner des
blessures ou des dommages matériels.
Lisez attentivement le mode d'emploi
fourni avec l'appareil. Pour obtenir de
l'aide ou des renseignements supplémen-
taires, consultez un installateur ou un
service d'entretien qualifi é ou le fournis-
seur de gaz.
Corporate Offi ce
Call: 800-544-4881
!
AVERTISSEMENT
®
CANADA
Dometic Corporation
46 Zatonski, Unit 3
Brantford, ON N3T 5L8
CANADA
Phone: 519-720-9578
MO-M 0624

Advertisement

Table of Contents
loading

Summary of Contents for Dometic RM3762

  • Page 1: Electric Operation

    Dometic Corporation Dometic Corporation 46 Zatonski, Unit 3 2320 Industrial Pkwy. Brantford, ON N3T 5L8 Elkhart, IN 46516 For Service Center Assistance CANADA Phone: 574-294-2511 Call: 800-544-4881 Phone: 519-720-9578 825125500 MO-M 0624 (French 825125550) ©2006 Dometic Corporation LaGrange, IN 46761...
  • Page 2: Table Of Contents

    INTRODUCTION This manual describes the installation procedure of RM3762 and RM3962. The installation is to be performed by qualified personnel only. Read this manual thoroughly before installing the refrigerator. Comply with installation specifications and dimensions. Follow the instructions to ensure that the refrigerator is installed safely and that it runs efficiently. Be aware of possible safety hazards when seeing alert symbols on the refrigerator as well as in this manual.
  • Page 3: Certification And Code Requirements

    1465 vent and one vent and one vent lower side vent. The ventilation kits shown in this RM3762 manual have been certified for use with RM 3762 and RM 3962. The table below displays the components and their RM3962 66-13/16 1697 part no.
  • Page 4: Installation

    INSTALLATION CLEARANCES SECURING THE REFRIGERATOR After the refrigerator has been installed (ensuring a combustion Minimum clearances (in inches) to combustible materials: seal at the front frame), the refrigerator must be secured in the Top (G) enclosure with six screws (not included). Furthermore, a lower Side (K) front strip (shipped as a loose part) should be attached.
  • Page 5: Drain Water Hose

    INSTALLATION DRAIN WATER HOSE Testing LP gas safety shut off Drill a hole through the flooring. Seal around the hose that goes The gas safety shut off must be tested after the refrigerator is through the drilled hole and ensure that it does not kink when connected to LP gas supply.
  • Page 6: Refrigerator Removal

    INSTALLATION 12V DC connection The refrigerator requires a continuous 12V DC supply to main- Ensure that the wires from the battery to the refrigerator are tain the automatic energy system. The connection is made to able to handle the load. The distance the current must travel the positive (+) and negative (-) terminals of the terminal block from the battery to the refrigerator dictates the AWG wire size on back of the refrigerator, see “...
  • Page 7: Mounting Instructions

    Panel dimensions max. thickness 5/32" (4 mm) Model Height Width RM3762 Attach the handle with two screws. upper inch 17-3/64 16-31/32 23-25/32 23-11/16 lower...
  • Page 8 MOUNTING INSTRUCTIONS To install the door panel, follow these steps: Snap on the handle. Remove the decoration strip by inserting a finger in the plastic profile and pull. Open the door 90 degrees. Insert the door panel’s edges into the grooves of the door frame.
  • Page 9: Appendix A - Technical Data

    APPENDIX A - TECHNICAL DATA Side view View from above MODEL RM3762 RM3962 DATA OVERALL DIMENSIONS Height (A) 1391 1624 inches 54-3/4 63-15/16 Width (B) inches 25-5/64 25-5/64 Depth (C) inches 26-1/16 26-1/16 RECESS DIMENSIONS Side view View from above...
  • Page 10: Appendix B - Rearview Equipment

    APPENDIX B - REARVIEW EQUIPMENT Heater Cover, Thermofuse Reigniter Flue baffle Power module cover Protection cover 12V DC Screw for protection cover 12 volt Terminal block Burner jet Drain water hose Manual gas Flexible cord shutoff valve Inlet fitting - 10 -...
  • Page 11: Appendix C - Wiring Diagram

    APPENDIX C - WIRING DIAGRAM - 11 -...
  • Page 12 TO THE INSTALLER PLEASE AFFIX THESE INSTRUCTIONS TO THE REFRIGERATOR — TO THE CONSUMER PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE...