Troubleshooting; Ultra-Flo Assembly; Junction Box Panel - Graco 243348 Instructions-Parts List Manual

Ultra–flo shot metering dispenser 2500 psi (17.2 mpa, 172.4 bar) maximum fluid working pressure
Table of Contents

Advertisement

Ultra–Flo Assembly
Problem
Ultra–Flo does not run.

Junction Box Panel

Problem
No power to solenoid valves,
proximity sensors, pressure
transducer.
t
d
Precision swirl motor doesn't op-
erate.
12
309280

Troubleshooting

Cause(s)
Over travel limit has been exceeded.
Over/Under Pressure Limits have been
exceeded.
Ball screw failure.
Electric motor failure (no power to mo-
tor).
Guide bearing failure.
Material inlet valve not functioning.
Throat seals binding.
Cause(s)
Voltage limits to circuit in junction box
exceeded.
One or more fuse(s) blown.
No power to junction box.
No power to motor.
No power to junction box from Robot
Controller.
Solution(s)
Reset per Robot Control Instruc-
tions.
Feed pressure too high / low. Re-
adjust per Robot Control.
Replace / rebuild ball screw.
Check power to motor, refer to Ro-
bot Control Instructions.
Check guide rails and bearings for
wear. Repair or replace as neces-
sary.
Refer to instruction manuals for
information.
Replace throat seals.
Solution(s)
Check surge suppressors SUP120
and replace if required.
Replace blown fuse(s). Check FU
117 and FU 120 on terminal block.
Check voltage to junction box from
Robot Controller. Refer to Robot
Instruction Manual.
Refer to Precision Swirl Instruction
Manual Graco part number 310554.
Check voltage to Pin 16 24DC+,
Pin 19 24DC–.