Prepare the Operator

All persons who operate the equipment must be
trained in the safe, efficient operation of all system
components as well as the proper handling of all fluids.
Every operator must thoroughly read all instruction
manuals, tags, and labels before operating the equip-
ment.

Initial System Startup Procedure

Follow the operating and system instructions provided
by the Robot Manufacturer.
WARNING
PRESSURIZED FLUID HAZARD
To reduce the risk of serious bodily inju-
ry, such as fluid injection or splashing
fluid in the eyes or on the skin, always
wear eye protection and protective cloth-
ing when installing, operating, or servic-
ing this dispensing system.
MOVING PARTS HAZARD
Moving equipment parts can cause per-
sonal injury, including severing of hands
or fingers. Make sure all personnel are
clear of moving parts before operating
the equipment.
CAUTION
The use of a non-compatible lubricant can cause
material contamination or inadequate performan-
ce. Use only a lubricant compatible with the material
to be pumped. Check with the material supplier for a
recommended lubricant.

Operation

Loading and Filling

1. Verify supply lines to the meter are filled.
2. Place the dispense valve over an appropriate
waste container.
3. Open the dispense valve and open the material
inlet valve to the meter. This will allow the system
to fill without restriction.
4. For the remainder of this procedure refer to the
instructions provided by the Robot Manufacturer.

System Shut Down

1. Shut off the main air supply to the system. This will
disable all outputs of the dispense system.
2. Shut down supply units in accordance with the
Pressure Relief Procedure on page 8.
3. Refer to system manual for other components.
WARNING
PRESSURIZED EQUIPMENT HAZARD
To reduce risk of injury or equipment
damage:
D Make sure all material hose connec-
tions are secure.
D Do not pressurize the system until
you have verified the system is ready
and it is safe to do so.
WARNING
PRESSURIZED FLUID HAZARD
To reduce the risk of serious bodily inju-
ry, such as fluid injection or splashing
fluid in the eyes or on the skin, always
wear eye protection and protective cloth-
ing when installing, operating, or servic-
ing this dispensing system.