High Altitude Duration Chart; Line Wiring Connections; Electrical Power - Johnson Controls DGAA Installation Manual

High efficiency sealed combustion gas furnace
Table of Contents

Advertisement

129098-UIM-G-0411
TABLE 4: High Altitude Duration Chart
56,000 — Input
Elevation
Orifice
Feet
Meters
Dia.
Sea Level
0.136
2,000
618
0.136
3,000
914
0.128
4,000
1219
0.128
5,000
1524
0.128
6,000
1829
0.128
7,000
2134
0.120
8,000
2438
0.120
9,000
2743
0.120
10,000
3048
0.116
56,000 — Input
Elevation
Orifice
Feet
Meters
Dia.
Sea Level
0.082
2,000
618
0.081
3,000
914
0.078
4,000
1219
0.078
5,000
1524
0.078
6,000
1829
0.076
7,000
2134
0.076
8,000
2438
0.073
9,000
2743
0.073
10,000
3048
0.070
Table shows 4% Input Reduction per 1,000 feet Elevation. Reference Source: NFPA No. 54, ANSI Z 223.1, National Fuel Gas Code.
For Canadian high altitude (2000 - 4500 feet), reduce gas manifold pressure to 3.0" W.C. for Natural gas, 9.0" W.C. for Propane gas
SECTION VI: ELECTRICAL POWER
Electrical Power Connections
Field wiring to the unit must be grounded. Electric wires that are field
installed shall conform to the temperature limitation for 63°F (35°C) rise
wire when installed in accordance with instructions. Refer to Table 5 in
these instructions for specific furnace electrical data.
Use copper conductors only.
SUPPLY VOLTAGE CONNECTIONS
1.
Provide a power supply separate from all other circuits. Install
overcurrent protection and disconnect switch per local/national
electrical codes. The switch should be close to the unit for conve-
nience in servicing. With the disconnect or fused switch in the OFF
position, check all wiring against the unit wiring label. Refer to the
wiring diagram in this instruction.
2.
Remove the screws retaining the wiring box cover. Route the
power wiring through the opening in the unit into the junction box
with a conduit connector or other proper connection. In the junction
box there will be three wires, a Black Wire, a White Wire and a
Green Wire. Connect the power supply as shown on the unit-wir-
ing label on the inside of the blower compartment door or the wir-
ing schematic in this section. The black furnace lead must be
connected to the L1 (hot) wire from the power supply. The white
furnace lead must be connected to neutral. Connect the green fur-
nace lead (equipment ground) to the power supply ground.
12
NATURAL GAS
70,000 — Input
Drill
Orifice
Drill
Part #
Size
Dia.
Size
29
9951-1361
0.154
23
29
9951-1361
0.149
25
30
9951-1281
0.149
25
30
9951-1281
0.147
26
30
9951-1281
0.144
27
30
9951-1281
0.144
27
31
9951-1201
0.140
28
31
9951-1201
0.136
29
31
9951-1201
0.136
29
32
9951-1161
0.128
30
PROPANE GAS
70,000 — Input
Drill
Orifice
Drill
Part #
Size
Dia.
Size
45
9951-0821
0.093
42
46
9951-0811
0.093
42
47
9951-0781
0.089
43
47
9951-0781
0.089
43
47
9951-0781
0.089
43
48
9951-0761
0.086
44
48
9951-0761
0.086
44
49
9951-0731
0.082
45
49
9951-0731
0.081
46
50
9951-0700
0.078
47
77,000 — Input
Orifice
Drill
Part #
Dia.
Size
9951-1541
0.161
20
9951-1611
9951-1491
0.157
22
9951-1571
9951-1491
0.157
22
9951-1571
9951-1471
0.154
23
9951-1541
9951-1441
0.152
24
9951-1521
9951-1441
0.149
25
9951-1491
9951-1401
0.147
26
9951-1471
9951-1361
0.144
27
9951-1441
9951-1361
0.140
28
9951-1401
9951-1281
0.136
29
9951-1361
77,000 — Input
Orifice
Drill
Part #
Dia.
Size
9951-0931
0.098
40
9951-0981
9951-0931
0.096
41
9951-0961
9951-0891
0.093
42
9951-0931
9951-0891
0.093
42
9951-0931
9951-0891
0.093
42
9951-0931
9951-0861
0.089
43
9951-0891
9951-0861
0.089
43
9951-0891
9951-0821
0.086
44
9951-0861
9951-0811
0.086
44
9951-0861
9951-0781
0.082
45
9951-0821
3.
The furnace's control system requires correct polarity of the power
supply and a proper ground connection. Refer to Figure 16.
BLK
BLK (HOT)
WHT
WHT (NEUTRAL)
GRN
GRN
FIGURE 16: Line Wiring Connections
LOW VOLTAGE CONTROL WIRING CONNECTIONS
1.
Insert 24 volt wires through the small plastic bushing just above
the control panel.
2.
Connect the thermostat wires to the furnace low voltage pigtails.
See Figure 17 (heating only) and Figure 18 or 19 (heating and
cooling).
3.
Connect thermostat wires to the furnace when installing blend air
accessory as shown in Figure 20.
4.
Connect low-voltage circuit to the wall thermostat pigtails.
NOTE: Five-conductor thermostat cable is recommended for all instal-
lations to allow easy installation of an air conditioning system at a later
time.
Set the heat anticipator in the room thermostat to 0.40 amps. Set-
ting it lower will cause short cycles. Setting it higher will cause room
temperature to exceed the set points.
90,000 — Input
Orifice
Drill
Part #
Part #
Dia.
Size
0.180
15
9951-1801
0.177
16
9951-1771
0.173
17
9951-1731
0.173
17
9951-1731
0.169
18
9951-1691
0.166
19
9951-1661
0.161
20
9951-1611
0.161
20
9951-1611
0.157
22
9951-1571
0.152
24
9951-1521
90,000 — Input
Orifice
Drill
Part #
Part #
Dia.
Size
0.106
36
9951-1061
0.104
37
9951-1041
0.101
38
9951-1011
0.101
38
9951-1011
0.099
39
9951-0991
0.098
40
9951-0981
0.096
41
9951-0961
0.096
41
9951-0961
0.093
42
9951-0931
0.089
43
9951-0891
NOMINAL