GE JB450GP Use And Care & Installation Manual page 31

Selficleaning electric range
Table of Contents

Advertisement

STEP 2
Use only a 3-conductor, or if required a 4-
conductor range cord set as noted below.
These cord sets are provided with ring
type terminals.
The electrical rating of the cord must be
125/250 volts minimum, 40 amperes.
NOTE: Only a 4-conductor cord is to be used
when the appliance is installed in a mobile
home or where local codes do not permit
grounding through the neutral.
STEP 3
1. Locate
connector block at the bottom
of range and remove rear wiring cover.
2. Directly below the connector block is a
hole with a knockout ring for accommodating
conduit fittings. Brackets provided are used to
support the flexible cord strain relief, which
must be securely attached to the cord set.
WIRING COVER
STEP 4
Power Cord Installation-Insert
through power cord terminals so that the
screws pass through connector block terminals
and engage nuts. Tighten screws securely.
TERMINAL
Cable Direct Installation-Clamp
rear
between the connector block terminals and
movable nuts with screws tightened securely.
BARE
MOVABLE
NUT ~
CTOR
1. Copper Wiring
Connect the neutral or grounded wire of the
supply circuit to the neutral terminal of the
connector block, located in the center. The
power leads must be connected to the outside
(brass colored) terminals.
GROUNDING STRAP
(GROUNDED TO RANGE)
SCREW +
POWER CORD
RING TERMINAL
I
/
MOVABLE
NUT
I
TERMINAL
I
screws
CORD
bare wires
FLEXIBLE
CABLE
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jb550gpJb551gp

Table of Contents