Honeywell Q7055B1047 Installation Instructions Manual

Open view net server (ovn)

Advertisement

Quick Links

Q7055B1047
Open View Net Server (OVN)
WARNING
This equipment generates, uses and can radiate
radio frequency energy, and if not installed and
used in accordance with the Instructions Manual,
may cause interference with radio communication.
It has been tested and found to comply with the
limits for a Class A computing device pursuant to
Subpart J of Part 15 or FCC Rules, which are
designed to provide reasonable protection against
such interference when operated in a commercial
environment. Operation of this equipment in a
residential area is likely to cause interference, in
which case, users at their own expense will be
required to take whatever measures may be
required to correct the interference. Any
unauthorized modification of this equipment may
result in the revocation of the owner's authority to
continue its operation.
The Q7055B1047 Open View Net Server (OVN) is a
Web-enabled operator interface that facilitates secure and
easy access to a Honeywell Building Management System
(BMS) through the Internet. It provides a connection of a
Honeywell XL5000 controller communication bus to an
industry standard TCP/IP Ethernet LAN/WAN, delivering
exceptional price/performance to meet the requirements of
both building owners and service providers.
With its combination of scalable performance, density and low
per - port pricing, the OVN allows network-layer capabilities to
be extended to a much wider range of network configurations
and environments. OVN supports a full range of Building
Management System (BMS) features such as commanding of
points as well as performing complex functions like alarm and
schedule management. Advanced features like graphics,
trends and reports give enhanced flexibility and total control
when accessing the Building Management System from a
remote location. Customers can now gain the advantages of
high-performance network and services, including traffic
management, to more locations throughout the network.
INSTALLATION INSTRUCTIONS
This INSTALLATION INSTRUCTIONS document covers the
following OVN server:
— Q7055B1047. Provides a single RS-485 DC coupled
C-Bus compatible communication channel for as many as
five Excel 5000™ family devices with up to 76.8 kbps and
single RS-232 and 10/100BaseT interfaces.
Additionally, each OVN is equipped with a RJ-45
10/100BaseT connector, plus an RS-232 interface.
(See Fig. 1).
INTERNET
BROWSER
OVN
SINGLE C-BUS
(ONLY FOR XL5000
CONTROLLERS
FAMILY)
Fig. 1. OVN network.
The Q7055B1047 OVN Server is used in systems for signaling
in energy management systems (UL 916). In addition, the
following standards apply: requirements of Canadian province
and local building codes; CEC 22.1 Canadian Code.
EBI
EBI
WORKSTATION
TCP/IP
OVN
SINGLE C-BUS
(ONLY FOR XL5000
CONTROLLERS
FAMILY)
M25198
95-7711

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell Q7055B1047

  • Page 1 Advanced features like graphics, The Q7055B1047 OVN Server is used in systems for signaling trends and reports give enhanced flexibility and total control in energy management systems (UL 916). In addition, the...
  • Page 2: Specifications

    4. Read the CONNECTIONS section carefully prior to connecting power and data interface cables to the OVN. 5. Refer to the INSTALLATION INSTRUCTIONS for each Models: Q7055B1047 Open View Net Server (OVN). component connected to the OVN: • Form no. 95-7481, Excel 100, 500, 600 Series.
  • Page 3: Wall Mounting

    Q7055B1047 OPEN VIEW NET SERVER (OVN) Wall Mounting Communications Panel Mounting It is also possible to mount the OVN server to a wall. The It is also possible to mount the OVN Server in the following sequence describes how the server should be 14006090-555151 series EBI Communications Panel prepared prior to mounting it on a wall (see Fig.
  • Page 4 PER NEC ARTICLE 760. ALL POWER LIMITED WIRING MUST BE SEPARATED FROM ALL NON-POWER LIMITED WIRING BY A MINIMUM DISTANCE OF 1/4 IN. (6 MM). M25120 Fig. 4. Typical mounting of Q7055B1047 OVN Assembly on 14006090-555151 series Communication Panel. 95-7711...
  • Page 5: Power Connection

    Field Bus Connection The 2-pole Phoenix connector (included) is used to connect to the field bus (see Fig. 12). Consult form no. 74-4022, Q7055B1047 Open View Net Server Checkout & Test for additional information on field bus wiring. CABLES AND CONNECTORS DB9F Null-Modem Connector See Fig.
  • Page 6: Ethernet Connection

    To connect a OVN Server to a LAN via an Ethernet Hub, the required cable should be configured as shown in Fig. 8. Finish the installation by commissioning the OVN in accordance with form no. 74-4022, Q7055B1047 Open View Net Server Checkout & Test. 95-7711...
  • Page 7: Operation

    Fig. 10. Excel 5000 Open View Net Server front panel. ® Jameco is a registered trademark of Arndt Electronics Corporation Enterprise Buildings Integrator EBI™ and Excel 5000™ are trademarks of Honeywell International, Inc. 95-7711...
  • Page 8 Q7055B1047 OPEN VIEW NET SERVER (OVN) Automation and Control Solutions Honeywell International Inc. Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Scarborough, Ontario M1V 4Z9 www.honeywell.com/buildingsolutions ® U.S. Registered Trademark © 2006 Honeywell International Inc.

Table of Contents