3.
Plug the power cord into the wall outlet, then turn on the treadmill with the ON/OFF switch.
4.
If necessary use conductive spray (Precor part number 37364-101) to ensure good contact
between the chest strap transmitter and the user, put on the heart rate chest strap
transmitter.Enter the diagnostics program per Procedure 2.1 or 2.2. Proceed to the heart
rate test portion of the diagnostics program. HArt will be displayed in the right display
window when the heart rate routine is accessed.
If the HEART RATE indicator blinks with your heart beat and the heart rate information
5.
displayed is correct...
THEN...
The Smart Rate system is operating
correctly. There is no need to continue
with this procedure.
Re-adjust the fit of the chest strap. If the HEART RATE indicator still does not blink as
6.
described in Step 4. If the chest strap transmitter has a replaceable battery, replace the
battery. If the HEART RATE indicator still does not blink as described in Step 5...
THEN...
Continue with the next step.
7.
Hold the Heart Rate Test Transmitter (Precor part number 20045-101) near the display
housing. If the HEART RATE indicator on the electronic console blinks with the LED on the
Smart Rate Test Generator...
THEN...
The chest strap assembly is bad.
Wear a new chest strap assembly
when you use the Smart Rate
System.
Press ENTER to return to the User ID.
8.
OTHERWISE...
Continue with the next step.
OTHERWISE...
The Smart Rate system is operating
correctly. There is no need to continue
with this procedure.
OTHERWISE...
The heart rate receiver assembly is
bad. Replace the heart rate receiver as
described in Procedure 5.4 of the
Residential Treadmill Service Manual.
9.45, 9.45i Treadmill
Page 25