Burnham 8B Series Installation, Operating And Servicing Instructions page 65

Gas fired boiler
Table of Contents

Advertisement

Figure 54: Honeywell Q314 Pilot Flame
(24V Standing Pilot)
Figure 55: Honeywell Q348 Pilot Flame
(24V Electronic Ignition)
Figure 56: Johnson J991 Pilot Flame
(24V Electronic Ignition)
Figure 57: Honeywell Q179D Pilot Flame (OP)
Figure 58: Honeywell Q179C Pilot Flame (EP)
I.
Check pilot burner flame and main burner flames
through observation port.
1. Check pilot flame. Refer to Table 11 for appropriate
pilot detail.
2. Adjust thermostat to highest setting.
3. Check main burner flames. See Figure 59. Flame
should have clearly defined inner cones with no
yellow tipping. Orange-yellow streaks caused by
dust should not be confused with true yellow
tipping.