SWIMMING POOL HEAT PUMP
T
D
RANSPORT
AMAGE
As soon as the unit is delivered to site, check
for evidence of freight damage. If there is any
damage, file a claim with the transport
company immediately, and contact your
Carrier representative.
L
U
OCATION OF
NIT
Consult local building codes for any
special building requirements and noise
level limitations.
Leave sufficient clearance around the unit
for service access and for proper air flow
through the unit.
Avoid complaints from neighbours by
locating the unit away from neighbouring
structures such as windows or hard
surfaces that might reflect and amplify
noise.
W
P
EATHER
ROOF
Carrier Heat Pumps are completely weather
proof and are suitable for mounting indoors
(e.g. garages, etc) or outdoors.
M
OUNTING
The unit should be mounted on a level base,
ideally a concrete slab, or equivalent
structure.
Installation &
Startup
Instructions
I
NDOOR
When mounted indoors, the Heat Pump outlet
should exhaust to outside and have a 600mm
minimum clearance on the side indicated
below, for service access. The Heat Pump
needs to draw air from inside the room, so
ensure there is some means for the air to
seep in. (wall grille, door grille, etc..)
water pipe
connections
Wiring access
024 - as shown.
036 & 065, drill
holes & fit
grommets as
necessary.
30ZQ024-G
30ZQ036
30ZQ065
30ZQ036
I
NSTALLATION
direction
of air flow
PLAN
VIEW
600mm min, clearance
for service access.
SIDE
ELEVATION
Page 1

Advertisement

loading

Summary of Contents for Carrier 30ZQ024-G

  • Page 1 EATHER ROOF Wiring access Carrier Heat Pumps are completely weather 024 - as shown. proof and are suitable for mounting indoors 036 & 065, drill SIDE (e.g. garages, etc) or outdoors. holes & fit...
  • Page 2 ITING The unit and its associated isolating switch must be installed no closer than 3.0m from ECHNICAL PECIFICATIONS the end of the pool. Model 30ZQ024-G 30ZQ036 30ZQ065 Voltage 220 - 240V 220 - 240V 380 - 415V Unlike solar panels, Heat Pumps are not Run Amps 10.5A...
  • Page 3 If the unit stops again, turn off the power and 5. If the Heat Pump is located lower than the call your Carrier representative or the water level of the pool, the 'head' of pool company you purchased the Heat Pump water may be sufficient to hold the water from.
  • Page 4 3. The compressor has a 1 to 5 minute time delay. The fan starts before the compressor. earth Specification may change without notice. Carrier Air Conditioning (NZ) Limited Carrier Air Conditioning Pty Ltd 25 Springs Rd 120-122 Terry St East Tamaki...

This manual is also suitable for:

30zq03630zq065