Component Specifications
To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before
servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires
removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.
Illustration
Component
A0282807
Bulb, upper refrigerator/freezer
A3079001
Bulb, lower refrigerator
M0360001
Bulb, cavity light
C8931608
Capacitor, auger motor
C8931612
Capacitor, compressor run
12049710
Compressor
R9900109
Control, damper
R0161092
Control, freezer temperature
RT1300056 Rev.1
!
WARNING
Test Procedure
Volt
Watt
Volt
Watt
Volt
Watt
Volt
Capacitance
Volt
Capacitance
Type
BTUH
Volt
Watt
Current
Lock rotor
Full load
Resistance
Run Windings
Start Windings
Settings
#1
#4
#7
Settings
#1
in
²
#1
²
out
#4
in
²
#4
²
out
#7
in
²
#7
out
²
2
120/125VAC
60 watts
115/125 VAC
40 watts
115/125 VAC
6 watts
210/220 VAC
15 Mfd +10%
-5%
220 VAC
15 Mfd +10%
-5%
Fan Cooled, R134a refrigerant
850 BTUH
115 VAC, 60 Hz
149 watts
21.3 amps
1.5 amps
2.60 ohms
4.35 ohms
Closing temperatures
47
F
40
F
30
F
Temperatures
21.0
F
4.5
F
13.3
F
-5.9
F
9.8
F
-11.0
F
October 2000