Protect Lines - Mitsubishi Electric WD-52526 Service Manual

Lcd projection hdtv
Hide thumbs Also See for WD-52526:
Table of Contents

Advertisement

COVER-DET
Status
[CD]
Engaged
OPEN
Sensor Status
LAMP-
FILTER-
TEMP
DET
[LT]
[CF]
Engaged
Engaged
Engaged
Engaged
Engaged
OPEN
OPEN
Engaged
Fan Status
PBS
LAMP
MD
[JB]
[JA]
[JC]
Drive:
Drive:
Drive:
10.04 V
10.04 V
6.01 V
Engaged
Engaged
Engaged
Engaged
Engaged
Engaged
Engaged
Engaged
OPEN
Engaged
OPEN
Engaged
OPEN
Engaged
Engaged
MODEL: WD-52526 / WD-62526
LAMP PROTECT LINE
LAMP_PROT.
LED
Voltage
Indicators
(KA/pin 14)
2.46 V
N/A
Lamp:
1.64 V
Yellow, blink.
ENGINE PROTECT LINE
ENG_PROT. Voltage
(FB/pin 9)
SENSOR-
DET
Specified Measured
[DT]
2.88 V ~
Engaged
2.82 V
2.68 V
OPEN
2.48 V ~
2.40 V
2.28 V
2.08 V ~
2.00 V
Engaged
1.88 V
Engaged
1.30 V ~
1.20 V
1.10 V
FAN DETECT LINE
FAN_DET Voltage
(FB/pin 9)
BALST
Specified Measured
[JF]
Drive:
3.02 V ~
7.02 V
2.92 V
Engaged
OPEN
2.82 V ~
2.72 V
Engaged
2.62 V ~
2.52 V
2.23 V ~
Engaged
2.13 V
1.44 V ~
Engaged
1.34 V
Page 35
Emergency
code
Comment
(Device+Menu)
Normal
N/A
condition
Turns OFF
32
fast
(1-2 sec).
LED
Emergency
Indicators
code
(Device+Menu)
N/A
N/A
Status:
46
Yellow.
Status:
33
Yellow,
blink.
Status:
38
Yellow.
LED
Emergency
Indicators
code
(Device+Menu)
3.00 V
N/A
N/A
2.80 V
Status:
2.60 V
Red,
blinking.
2.20 V
1.40 V
Comment
Normal
condition
Turns OFF
fast
(1-2 sec).
Turns OFF
fast
(1-2 sec).
Turns OFF
slowly
(25-30
sec).
Warning on
screen.
Comment
Normal
condition
36
Turns OFF
fast
37
(1-2 sec).
42
45

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wd-62526

Table of Contents