Pressure Control Replacement

WARNING
FLUID INJECTION HAZARD
To reduce the risk of serious injury,
follow the illustrated Pressure Relief
Procedure warning on page 13 when-
ever you are instructed to relieve pressure.
1. Relieve pressure.
2. Disconnect the filter/drain valve assembly and the
pump supply hose at the pressure control while
holding the pressure control fitting (A) firmly. See
the CAUTION, below. See Fig. 17.
CAUTION
Do not allow the fittings (A) to turn when removing
or connecting the hose and filter/drain assembly.
Do not over tighten the screws when attaching the
pressure control board/cover. Turning the fittings or
over tightening the screws may shift the calibration
of the pressure control.
TO GUN
Fig. 17
3. Remove the four mounting screws and washers
(302, 303, 304) from the pressure control board/
cover (301). See Fig. 18.
4. Carefully remove the pressure control board/cover
(301) so as not to stress the cables.
5. Remove the potentiometer cable (310) from the
pressure control board/cover (301).
6. Disconnect the pressure control board/cover
black/white M+ and black M– leads from the motor
+ and– leads.
7. Disconnect the red motor leads from the TS termi-
nals on the pressure control board/cover (301).
8. Disconnect the black power lead (L1) from the
ON/OFF switch.
9. Disconnect the white power lead (L2) from the
power cord (314) to the pressure control
board/cover (301).
10. Loosen the ground terminal screw (317) and
disconnect the ground lead (C).
11. Pull off the pressure control board/cover.
301
A
FILTER/DRAIN
VALVE ASSEMBLY
TO PUMP
A

Advertisement