Maintenance Instructions - Napoleon GS3500 - N Installation And Operation Instructions Manual

Natural & propane gas-fired stove
Table of Contents

Advertisement

10
FOR YOUR SAFETY READ BEFORE OPERATING
A. This fireplace is equipped with a pilot which must be lit by hand while following these instructions exactly.
B. Before operating smell all around the fireplace area for gas and next to the floor because some gas is heavier than air and
will settle on the floor.
WHAT TO DO IF YOU SMELL GAS:
• Turn off all gas to the fireplace.
• Open windows.
• Do not try to light any appliance.
C. Use only your hand to turn the gas control knob. Never use tools. If the knob will not turn by hand, do not try to repair it. Call
a qualified service technician. Force or attempted repair may result in a fire or explosion.
D. Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the
fireplace and replace any part of the control system and any gas control which has been under water.
LIGHTING INSTRUCTIONS:
until the thermocouple has cooled. Allow approximately 60 seconds for the thermocouple to cool.
When lighting and re-lighting, the gas knob cannot be
turned from pilot to off unless the knob is depressed
slightly.
1.Stop! Read the above safety information
on this label.
2.Turn off all electric power to the fireplace.
3.Turn the gas knob clockwise
4.Wait five (5) minutes to clear out any gas. If you smell
gas including near the floor. Stop! Follow "B" in the
above safety information on this label. If you don't
smell gas go the next step.
INSTRUCTIONS TO TURN OFF GAS:
1.Turn off all electrical power to the unit if service is
to be performed.

MAINTENANCE INSTRUCTIONS

MAINTENANCE INSTRUCTIONS
MAINTENANCE INSTRUCTIONS
MAINTENANCE INSTRUCTIONS
MAINTENANCE INSTRUCTIONS
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing. This stove and its venting system should be inspected before use and at
least annually by a qualified service person. The area around the stove must be kept clear and free of combustible materials,
gasoline and other flammable vapours and liquids. The flow of combustion and ventilation air must not be obstructed.
1.In order to properly clean the burner and pilot assembly, remove the logs exposing both assemblies.
2.Keep the control compartment, logs, burner, air shutter opening and the area surrounding the logs clean by vacuuming or
brushing, at least once a year.
3.Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or are not burning
properly.
4.Check to see that the pilot flame is large enough to engulf the thermocouple on one leg and reaches toward the burner on
the other leg.
5.Replace the cleaned logs.
6.Check to see that the main burner ignites completely on all openings when the gas knob for the burner is turned on. A 5-
10 second total light-up period is satisfactory. If ignition takes longer, consult your Napoleon dealer/distributor.
7. After extended periods of non-operation such as following a vacation or a warm weather season, the fireplace may emit
a slight odour for a few hours. This is caused by dust particles in the heat exchanger burning off. Open a window to sufficiently
ventilate the room.
WS-415-55 / 11.10.97
• Do not touch any electric switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbour's phone.
Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
The gas valve has an interlock device which will not allow the pilot burner to be lit
WARNING
5.Turn gas knob counter-clockwise
6.Depress slightly and hold gas knob while lighting the pilot with
the push button ignitor. Keep knob depressed for one minute,
then release. If pilot does not continue to burn, repeat steps 3
through 5.
7.With pilot lit, depress and turn gas knob
GAS KNOB
counter-clockwise
to off.
8.If equipped with remote on-off switch/ther-
mostat, main burner may not come on when you turn valve to
on. Remote switch must be in the on position to ignite burner.
9.Turn on all electric power to the fireplace.
TURN OFF THE GAS AND UNPLUG ELECTRICAL POWER BEFORE SERVICING THE STOVE.
to on.
2.Push in gas control knob slightly and turn clockwise
to off. DO NOT FORCE.
to pilot.
PIEZO
IGNITOR
FLAME
ADJUSTMENT
KNOB
PILOT
VARIABLE
ON/OFF
SPEED
KNOB
SWITCH

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gs3500-p

Table of Contents