10. The boiler should be tested to verify the high limit and dump zone is working properly, simply adjust the
high limit until the boiler shuts off and verify that the dump zone operates and that the boiler comes
back on within 5 degrees of the set point (there is a small white wheel under the terminals that should be
set on 5 to accomplish this).

In Season Maintenance

1. Check Elbows and horizontal pipe runs for fly ash build up every ton of coal used, clean as needed.
2. Clean under the feed carpet every two or three months.
3. Clean combustion fan.
4. Oil fan motor every two months or so with 1 drop of 30W5 synthetic oil.
5. Burn oiled coal if possible, this will reduce coal dust in the boiler area and therefore reduce
maintenance.
6. Power off boiler and clean combustion fan squirrel cage fins every two months, depending on level of
dust in area of boiler, may be required more frequently.
7. Refer to Power Vent manual for cleaning and maintenance instructions.
DANGER - Risk of Fire or Explosion - Do not burn garbage, gasoline, drain oil or other flammable liquids.
CAUTION – HOT SURFACES – KEEP CHILDREN AWAY – DO NOT TOUCH APPLIANCE DURING OPERATION
DO NOT CONNECT THIS UNIT TO A CHIMNEY SERVING ANOTHER APPLIANCE
WARNING –
RISK OF FIRE – DO NOT OPERATE WITH A FLUE DRAFT EXCEEDING -.07" wc,
OPERATING AT A DRAFT ABOVE -.07" wc CAN CAUSE UNIT TO BURN BACK INTO THE HOPPER
DO NOT OPERATE WITH ASH REMOVAL DOOR OPEN
DO NOT STORE FUEL OR OTHER COMBUSTIBLE MATERIAL WITHIN MARKED INSTALLATION CLEARANCES
CAUTION – BURN RICE OR BUCKWHEAT SIZED ANTHRACITE COAL ONLY
PLEASE SAVE THESE INSTRUCTIONS
Standard Sheet Metal
cover and Insulation
Optional Flue Clean Out
and Sheet Metal Cover

Advertisement

Table of Contents
loading

Table of Contents