6-1. OVERVIEW

From time to time the KDP-57XBR2/65XBR2 may require an
upgrade to its firmware.
The Q-box inside the set allows for upgrading the firmware via a
®
Memory Stick
slot. At such times that upgrades are required,
pre-programmed Memory Sticks will be made available to the
service network. Be sure to check the Sony Service Company's
web site to see if any upgrades are available for correcting the
problems you are trying to resolve.
DISCLAIMER:
Any use of the Memory Stick port for any reason
other than a Sony authorized upgrade will void
the product warranty. All related repair charges
will be the responsibility of the customer.
6-2. TRANSFERRING THE NEW FIRMWARE
FROM THE MEMORY STICK TO THE
Q-BOX.
1. Turn the PJ on.
2. Insert the Memory Stick containing the new firmware into
the Memory Stick slot on the back of the set.
3. If the inserted Memory Stick is the correct type, and its files are
correct for the KD-57XBR2/65XBR2 and are not damaged
(corrupted), the upgrade process will begin automatically. The
screen will display "Memory Upgrade Mode" for 3 seconds,
after which the screen will go black until the upgrade is completed.
NOTE: The user controls are inoperative while this
upgrade is in progress.
4. A status LED is located above the Memory Stick slot. This
LED will flash in several distinct patterns dependent upon
the status of the upgrade, as follows:
0s
1s
Pending/
Busy
Success
Memory
Stick Error
Flash
Error
System
Error
Key:
LED On
LED Off
Fig. 6-1
SECTION 6

FIRMWARE UPGRADES

5. When the status LED flashes the "Success" pattern shown
6. If the status LED flashes the "Flash Error" (flash memory)
7. If the status LED flashes the "Memory Stick Error" pattern
2s
3s 3.2s
– 52 –
Fig. 6-1, the upgrade has completed successfully. Remove
the Memory Stick and the set will return to the operating
state it was in before the upgrade began.
pattern or the "System Error" pattern shown above, remove
the Memory Stick and start over again from step 1.
you must obtain a new Memory Stick and start over from
step 1.
Rear View
Terminal Board
SERVICE
ONLY
Memory Stick Input Location
Fig. 6-2
KDP-57XBR2/65XBR2
RM-Y185