Summary of Contents for Teracue ENC-100 MPEG-2 Encoder
Page 1
2 Encoder User Guide V User Guide V3 3 3 3 ..0 0 0 0 6 6 6 6 User Guide V User Guide V Teracue AG Schlossstr. 18 85235 Odelzhausen Germany +49 (0)8134 555 10 info@teracue.com...
Scope This user guide is designed to help users setup, configure and work with the This user guide is designed to help users setup, configure and work with the This user guide is designed to help users setup, configure and work with the This user guide is designed to help users setup, configure and work with the MPEG MPEG- - - - 2 encoder...
• GPI enabled. Encoder streaming on/off can be remotely controlled by GPI • (Please enquire at support@teracue.com) Comport for RS-232/485 operation is supported and settings are adjustable via GUI • Comport support for RS-232 and 485 via jumper setting has been added •...
Page 5
V3.03 - released 2006-03-20 Automatic aspect ratio 4:3/16:9 encoding added. • If WSS (wide screen signal) is found in video input signal and encoder is set to "Auto" aspect ratio, the ENC-100 will set the correct aspect ratio flag within MPEG TS stream. WSS detection and auto aspect ration for both PAL and NTSC.
III. Table of Contents I. Scope ....................3 Version 3.05 release notes ............4 III. Table of Contents................6 ENC-100 Overview .................8 Unpacking the encoder.................. 10 Setting up the encoder and safety instructions .......... 11 Connecting the encoder (FR-100 chassis) ........... 12 1.3.1 Audio input/output....................13 1.3.2 LED-Status Indicator.....................13...
Page 7
2.4.12 : XP ....................49 LAYER Help........................50 Logout ......................51 Extended Functions..............52 Telnet....................... 52 Serial Connection................... 56 Audio Talkback....................60 3.3.1 Unicast Stream to XPlayer..................62 3.3.2 Multicast Stream to XPlayer..................63 Resetting to factory defaults ................. 64 CE, FCC conformance ..............65 Restriction of Hazardous Substances Directive (RoHS) ...65 Waste Electrical and Electronic Equipment Directive (WEEE) .66 Technical Specifications .............67...
21 ENC-100 encoder cards. A perfect fit, where there is little space, yet many encoding channels are required Teracue offers 2 models of the high density frame rack. The FR-1000 is supplied with a single power supply; the FR-2000 is fitted with a dual, redundant power supply.
Page 9
The ENC-100 supports output processing and streaming of both NTSC and PAL composite video signals and full stereo audio. Encoder bitrates can be set according to your needs from 800Kb/s - 15Mb/s. MPEG-2 Streams are encoded at ML@MP 4:2:0 and can be streamed by means of unicast or multicast traffic into your network.
1.1 Unpacking the encoder When you unpack the ordered equipment please make sure all the equipment is complete. Normally the ENC-100 blades are pre-fit into the according chassis that the encoders have been ordered with. If ENC-100 blades are ordered and shipped separately, please be careful when handling the blades.
1.2 Setting up the encoder and safety instructions Always read the instructions carefully and keep this user guide for future reference. Always read the instructions carefully and keep this user guide for future reference. Always read the instructions carefully and keep this user guide for future reference. Always read the instructions carefully and keep this user guide for future reference.
1.3 Connecting the encoder (FR-100 chassis) Connect the power supply here. The cable connector can be locked to the socket of the encoder, so the cable cannot The cable connector can be locked to the socket of the encoder, so the cable cannot The cable connector can be locked to the socket of the encoder, so the cable cannot The cable connector can be locked to the socket of the encoder, so the cable cannot accidentally be pulled out [Bayonet Socket].
1.3.1 Audio input/output The following picture displays the connector assignment for the mini jack audio input and output of the ENC-100. It follows the standardized mini jack pin assignment. The Line-In level for Audio-In is 1VRms on 10KOhm. The level cannot be decreased by using the Audio Codec (AC97 standard). Some manufacturers have 2VRms as input level and use an external attenuator.
ENC- - - - 100 GPIO version 100 GPIO version 100 GPIO version 100 GPIO version Teracue can modify the ENC-100 according to the use of the GPI function without external power. This modification has to be specified in the order.
Page 15
GPIO CONNECTOR Connectors, Pins on ENC-100 blade As this is only necessary for special operating modes, please contact support@teracue.com for further information. GPO will be supported with the next firmware version releases. Please see chapter 2.4.10.2 – Firmware Update for more information.
1.3.4 Audio output The audio output acts like an audio decoder. It enables operating the ENC-100 with Full Duplex Audio. For example an encoder can be set up to encode video and audio from a camera that is installed at an entrance (security application). The person who wants to enter is able to speak into a microphone to state his/her name, etc.
Working and configuring Teracue's encoders is very easy. You do not need to install an application or remote configuring software. If you know how to browse the internet, then you already know how to access and control the encoders, simply via web-browser.
1. If you have an ENC-100 COMCAB (optional) see chapter 3.2 2. Reset the ENC-100 to the factory defaults. See chapter 3.4 If you need further information please contact: support@teracue.com...
2.2 Login After typing the IP- address into the browser and hitting enter, the following login screen should appear. Enter your U SERNAME and P ASSWORD click on L OGIN (admin/admin).
2.3 User interface 2.3.1 Navigational Menus After successful login you have access to the encoder's configuration. All of the settings can be adjusted via web-browser. MAIN MENU: MAIN MENU: MAIN MENU: MAIN MENU: Select between NCODER ETWORK and S YSTEM ETTINGS from the top bar.
2.3.2 Apply and save buttons A change or multiple changes of the configuration settings will only take effect after the A is pressed. PPLY BUTTON The encoder will then start working with the new parameters, BUT the parameters will not be saved to the encoder. Applied settings are not saved and will be lost after a reboot.
2.4 Encoder configuration 2.4.1 Menu: E NCODER ETTINGS Under the menu option E you define the main operational state of the NCODER ETTINGS encoder. Set encoding to , and specify the S TREAMING ORMAT ETTINGS ESCRIPTION Page Refresh: If the Check-box is checked, the web-side will be refreshed every 10 seconds.
Page 23
Stream Mode: Select a Stream Mode: TS - Transport Stream (low latency: Video + Audio) TS (video only) TS (audio only) VES - Video Elementary Stream (lowest-latency: Video only) AES – Audio Elementary Stream (lowest-latency: Audio only) Video Locked: Displays the status of the input video: = Video Input OK = Video Input Missing Bytes Transferred:...
2.4.2 Menu: E NCODER RANSPORT In the E menu, you are able to specify the encoders T and set NCODER RANSPORT RANSPORT the Video, Audio and PCR PIDs. PID stands for Packet Identification. The PIDs help to identify and locate the elementary signals in a stream containing lots of different information and signals (audio, video and data).
2.4.3 Menu: E NCODER IDEO This menu lets you define the V IDEO NCODING ROPERTIES HOOSE BET WEEN ENCODING WITH A ONSTANT (CBR), OR A ARIABLE (VBR). .!. We recommend CBR. G G G G = = = = MPEG MPEG T T T T G G G G O O O O...
Page 26
Choose between NTSC and PAL composite video input format. Choose the Aspect Ratio (See 2.4.3.1) .!. We recommend “auto” RIGHTNESS ONTRAST ATURATION Video encoding resolution The Brightness, Contrast and Four different resolutions can be selected. Saturation of the encoded video You can choose between: stream can be controlled by these Full D1...
2.4.3.1 Aspect Ratio The ENC-100 supports encoding and streaming of signals with different aspect ratios (4:3/16:9) since firmware version 3.01. If an analogue input signal includes the WSS (Wide Screen Signal) the ENC-100 can detect whether the input signal is in 16:9 or in 4:3, when menu “Aspect Ratio” is switched to “auto”. The Wide Screen Signal is included in the first half of line 23 in the PAL standard video signal.
2.4.3.2 GOP Type Overview (I, IP, IBP, IBBP) .!. .!. .!. .!. We recommend using We recommend using only only Real Closed GOPs Real Closed GOPs! ! ! ! These These are marked above by the are marked above by the We recommend using We recommend using only...
2.4.4 Menu: E NCODER UDIO .!. Audio will not .!. Audio will not .!. Audio will not .!. Audio will not be encoded if you be encoded if you be encoded if you be encoded if you are encoding a are encoding a are encoding a are encoding a...
2.4.5 Menu: E /SAP NCODER SAPs are Session Announcement Protocols. A SAP is used to label a stream to guarantee an effective workflow. Streams with SAPs can easily be located, selected and viewed – due to their description. Please see the screen below to get an overview of all the properties that can be defined.
2.4.6 Menu: E NCODER ESTINATION ENC-100 is capable of sending out the encoded stream as either a unicast stream or a multicast stream. According to the entered destination IP-address, the encoder will automatically recognize if it's supposed to send out a unicast or multicast stream. Enter the destination IP- address...
IN pin circuit is closed. When IN pin circuit is open, the ENC-100 will not generate a stream. (Out and middle pins are not yet supported.) GPIO ADAPTER (Black GPIO Adapter) GPIO CONNECTOR Connectors, Pins on ENC-100 blade As this is only necessary for special operating modes, please contact support@teracue.com for further information.
GPO will be supported with the next firmware version releases. Please see chapter "Firmware Update" for more information. .!. .!. .!. .!. If no GPI IN switching device is connected to the ENC If no GPI IN switching dev ice is connected to the ENC- - - - 100 the setting on this menu 100 the setting on this menu If no GPI IN switching dev If no GPI IN switching dev...
Page 34
.!. .!. .!. .!. When the IP When the IP- - - - address has been changed, the encoder needs to be reset (reboot), in address has been changed, the encoder needs to be reset (reboot), in When the IP When the IP address has been changed, the encoder needs to be reset (reboot), in address has been changed, the encoder needs to be reset (reboot), in...
.!. Set your SNMP manager to SNMPv2. .!. Set your SNMP manager to SNMPv2. Teracue uses the MIB Browser by iReasoning to monitor/set up the ENC-100. iReasoning offers a free version of the MIB Browser under www.ireasoning.com, which is useful to read the actual status or setting up the ENC-100.
Page 36
ENC-100 SNMP Settings To use the ENC-100 SNMP features, you have to set up the encoder, to establish access with your SNMP manager. SNMP Settings SNMP Settings SNMP Settings SNMP Settings Manager IP: To receive TRAPs, enter the IP Address of the Client PC were the SNMP manager (TRAP Receiver) is installed GET community: Type in the password for the GET community which you have to enter...
Page 37
Setting up the MIB Browser Load the MIB files Click on File > Load MIB and choose the folder with the MIB files: You have to load both files; TERACUE You have to load both files; TERACUE- - - - ENC100 ENC100- - - - MIB.txt and TERACUE...
Page 38
Type in the “Write Community” password. The default password of the ENC-100 is “private” Set the SNMP Version to 2 Choose the loaded Teracue ENC-100 MIB and right click on it. Click on “Expand subtree” to see all options of the ENC-100.
Page 39
The opened subtree shows you all the adjustable options, you also have with the web interface. The next example shows you how to use the MIB Browser, explained by the ENC-100 menu item “videoBitrate”. Right click on the option “videoBitrate”. You can now choose “Get”...
Page 40
Integer: Read-only/read-write normal numbers in the possible range of Integer32: Read-only normal numbers in the possible range of Octet String: Read-only/read-write numbers and characters (e.g. Teracue) IPAddress: Read-only/read-write numbers in the IP address string (e.g. 172.16.20.100) Access The attribute read-only or read-write shows you if you can change the selected item or if you...
Page 41
SNMP devices that can be controlled by a SNMP manager. The following list shows an example of the available devices. In this case the ENC-100 sysDescr: The Name of the network device: e.g. Teracue ENC-100 sysObjectID: This shows the explicit MIB ID of the device.
2.4.10 Menu: C OMPORT ETTINGS This menu defines the parameters for the ENC's integrated comport/serial port. Mode: – enables access and control of the ENC-100 configuration via ONSOLE the com-cable (ENC-100-COMCAB). Use this cable to set the ENC configuration if you do not want to use web access. –...
2.4.10.1 Setting RS-232 or RS-485 To change the support of RS-232 or RS-485 devices, please power down the encoder chassis and remove the ENC-100 blade gently from the chassis. Hold the encoder blade as shown below, with the video input pointing to the left. RS-232 setting: For supporting RS-232 devices on the comport the red jumper must be situated on the pair of left pins, as shown below.
2.4.10.2 Example code for a Panasonic X?X camera The application was used to send commands to a camera, waiting for a status and returning a command. #include <stdio.h> #include <stdlib.h> #include <string.h> #include <unistd.h> #include <getopt.h> #include <sys/types.h> #include <sys/stat.h> #include <fcntl.h>...
2.4.11 Menu: S YSTEM ETTINGS The menu S displays information about the firmware version that is installed on YSTEM ETTINGS your ENC-100. After the firmware version number you will find either: CVBS for Composite images (FBAS), Y/C for S-Video firmware images or SDI. The encoder's MAC A is also listed under this menu.
2.4.11.1 Menu: S YSTEM ASSWORD .!. .!. .!. .!. Unless your encoder is used in very critical scenarios, we recommend to leave the Unless your encoder is used in very critical scenarios, we recommend to leave the Unless your encoder is used in very critical scenarios, we recommend to leave the Unless your encoder is used in very critical scenarios, we recommend to leave the password set to it password set to its s s s default value ("admin", "admin").
3.03 3.03 Firmware versions can be downloaded from the Teracue support website listed above. Download the correct firmware version that you wish to update your encoders with and save it locally on your computer. The firmware version file e.g. for version 3.03 Y/C, S-Video is called: "enc...
2.4.12 : XP LAYER The menu XP starts the Standalone XPlayer, if a XPlayer is installed on the client PC. You LAYER can start the XPlayer by clicking the XPlayer-Link inside the menu. Afterwards the XPlayer automatically displays the stream of the ENC-100. .!.
2.5 Help Clicking on the help button will open the Teracue ENC-100 user manual (this document) directly from the Teracue website. Your ENC-100 automatically connects to open the most current version of the user guide. .!. .!. .!. .!. This...
2.6 Logout After having made adjustments to the encoder, please be sure to logout. .!. .!. .!. .!. Logging out prevents misuse and unauthorized access Logging out prevents misuse and unauthorized access to to to to the the ENC ENC- - - - 100 100.
3. Extended Functions 3.1 Telnet A further way to communicate with the ENC-100 blade instead of accessing it by a web browser is to connect via telnet. Telnet is a terminal emulation program that runs on your computer and connects your PC with the ENC-100 over the network. To start a telnet session under windows you must open the commando prompt tool.
Page 53
For starting a telnet session type: telnet <ip telnet <ip telnet <ip- - - - address>, telnet <ip address>, address>, address>, e.g. telnet 172.16.20.100 The IP address should correspond to the ENC's IP address. This will open the following dialog. Enter your Login Name Password.
Page 55
status/ status/ status/ status/ system/ system/ system/ system/ software_version software_version Software software_version software_version uptime uptime uptime uptime System uptime cpuload cpuload cpuload cpuload CPU Load temperature temperature Temperature temperature temperature 3.3Vin 3.3Vin 3.3Vin 3.3Vin 3.3 V in 5.0Vin 5.0Vin 5.0Vin 5.0Vin 5.0 V in mac_address...
ENC-100 com-cable (ENC-100-COMCAB). The com-cable is an optional ENC accessory, and needs to be ordered separately. For more information contact: support@teracue.com The pin assignment for the RJ45 female COM-port interface of the ENC-100 is: Pin 1: not connected...
Page 57
When Hyper Terminal is started you will be presented with the “Connection Description” “Connection Description” “Connection Description” “Connection Description” dialogue box. Type in a session name (e.g. ENC-100) and click OK After the “Connect “Connect To To” ” ” ” window will open, click “Connect “Connect on the arrow for the “Connect Using”...
Page 58
Adjust the following attitudes for a successfully connection. Bits per second: 38400 Data bits: Parity: None Stop bits: Flow control: None Click OK Now start or restart your ENC-100. Afterwards you will see the following screen:...
Page 59
Enter your Login Name and Password. (The same password as during the registration in the browser: admin/admin) The structure of directories and options are the same as at the Telnet connection (chapter 3.1) , so you have to use the same commands for changing and applying values. .!.
TALKBACK..zip zip" " " " – – – – You will find the Zip-folder in the IPTV support Area on TALKBACK TALKBACK www.teracue.com, inside the Encoder support section. The ENC-TALKBACK.zip includes the following files: - audioplugin.ocx: ActiveX control - install.bat: Installation file - audio_test.html...
Page 61
To change the IP Address (e.g. 172.16.100.100) of the encoder, to which you would like to send your microphone audio signals, open the attached Webpage (audio_test.html or index.html) in a text editor. The audio signals from the microphone that is connected to your PC will be sent and output on the ENC-100 on the analog audio output.
3.3.1 Unicast Stream to XPlayer The ENC-100 can not only stream by multicast. You can also choose unicast to stream to a single destination. To view the unicast stream you can use the XPlayer. Just follow the next instructions. ENC-100: Go to Encoder > Destination Enter the IP address of your PC, where the XPlayer is installed, as “Destination IP address”.
3.3.2 Multicast Stream to XPlayer To open a Multicast Stream manually you can enter the following string under “URL” in the “Video Select” window of the XPlayer. (see previous page) Enter icue:// followed by the Multicast IP address of the Stream with the corresponding port number.
3.4 Resetting to factory defaults The ENC-100 blade can easily be returned to its factory default values (IP 172.16.20.100). In order to do this please power down the encoder chassis and remove the blade gently and carefully from the chassis. 1.
Since beginning of 2005, Teracue AG began the process of redesigning and converting all of its products to not contain any of the listed materials. All new products sold by Teracue will its products to not contain any of the listed materials. All new products sold b y Teracue will its products to not contain any of the listed materials.
WEEE and saving the environment by separating out WEEE and disposing of it properly. Teracue AG is a registered WEEE parti Teracue AG is a registered WEEE participant since 2004. Within Germany, cipant since 2004. Within Germany, Teracue AG is a registered WEEE parti Teracue AG is a registered WEEE parti cipant since 2004.
8. Known Issues 1. GPIO OUT support will be added in a future firmware release. 2. When encoding a Transport Stream with audio only, users may experience an issue regarding audio drop outs every 80 seconds.
Need help?
Do you have a question about the ENC-100 MPEG-2 Encoder and is the answer not in the manual?
Questions and answers