CARAVAN EQUIPMENT
Chapter 4
TRUMA TRIOMATIC AUTOMATIC GAS CHANGE-OVER SYSTEM
Operating instructions
Warning: Always ensure that the gas cylinders are in an upright position
and secured against tipping over.
The operating and reserve cylinder regulators (6+7) have combination
fittings for the cylinders. Always assemble the regulators (6+7) in such a
way that the blue safety caps are facing upwards.
Caution: do not kink or severely bend the gas hoses.
First open the valve on the reserve cylinder (red type plate) and then
open the valve of the operating cylinder (green type plate) Both regulators
are now vented. The system regulator (marked with a yellow type plate
for 30mbar) supplies the caravan appliances with the correct pressure
68