12.15. e-ion Operation

1. Purpose
This operation provides clean air by producing negative ions to attract dust captured at the positively charged e-ion filters.
2. Control Condition
a. e-ion operation start condition
• During unit running at any operation mode, if "e-ion" button is pressed, combination operation (operation mode + e-ion
operation) starts.
• During unit is OFF, if "e-ion" button is pressed, e-ion individual operation starts.
b. e-ion operation stop condition
• When "OFF/ON" button is pressed to stop the operation.
• When "e-ion" button is pressed again.
• When "Patrol" button is pressed.
• When OFF Timer activates.
c. e-ion operation pause condition
• When indoor fan stop (during deice, odor cut control, thermostat off, etc.). e-ion operation resume after indoor fan
restarts.
• When indoor intake temperature
30 minutes.
40°C. e-ion operation resume after indoor intake temperature < 40°C continuously for