Figure 24. Removing the microprocessor
10. Close the microprocessor retainer and lock it into position with the small
11. Reinstall the heat sink and fan assembly. See "Replacing the heat sink and fan
12. Reinstall any other parts or reconnect any other cables you removed.
13. Go to "Completing the parts replacement" on page 61.
50
ThinkServer TS200v Types 0981, 0992, 1008, and 1010: Hardware Maintenance Manual
c. Touch only the sides of the microprocessor. Do not touch the gold contacts
on the bottom.
d. Do not drop anything onto the microprocessor socket while it is exposed.
The socket pins must be kept as clean as possible.
7. Make sure that the small handle is in the raised position and the
microprocessor retainer is fully open.
8. Hold the new microprocessor and align the notches on it with the alignment
keys in the microprocessor socket, or align the small triangle on one corner of
the new microprocessor with the corresponding beveled corner of the
microprocessor socket.
9. Lower the new microprocessor straight down into the microprocessor socket
on the system board.
handle to secure the new microprocessor in the socket.
assembly" on page 47.