Kenwood UBZ-LJ8 Service Manual page 19

Hide thumbs Also See for UBZ-LJ8:
Table of Contents

Advertisement

PLL Section
Item
Condition
1. VCO lock voltage 1) 4CH : 446.04375MHz
RX
TX
2) 4CH : 446.04375MHz
PTT : ON
2. Reference
1) 4CH : 446.04375MHz
oscillator
PTT : ON
frequency
Transmitter Section
Item
Condition
1. TX power
1) 1CH : 446.00625MHz
and current
PTT : ON
2. MAX
1) 1CH : 446.00625MHz
deviation
AG : 1kHz/100mV
PTT : ON
3. MIC
1) 1CH : 446.00625MHz
sensitivity
AG : 1kHz/5mV
PTT : ON
4. CTCSS
1) Enter the adjustment mode,
deviation
then write the CTCSS
deviation level.
1CH : 446.00625MHz
Tone No. : 24 (151.4Hz)
PTT : ON
2) Tone No. : 38 (250.3Hz)
PTT : ON
Receiver Section
Item
Condition
1. Quad-coil
1) 4CH : 446.04375MHz
adjustment
SSG output : –53dBm (501µV)
SSG MOD : 1kHz
SSG DEV : 1.5kHz
AF VOL : 10 o'clock position
2. Sensitivity
1) 4CH : 446.04375MHz
SSG output : –115dBm (0.398µV)
SSG MOD : 1kHz
SSG DEV : 1.5kHz
AF VOL : 0.63V/8Ω
CCITT filter : ON
3. Squelch
1) 4CH : 446.04375MHz
SSG output : –116dBm (0.35µV)
2) SSG output : –127dBm (0.1µV) Oscilloscope TX-RX SP
4. BATT
1) BATT terminal
: DC 3.35V± 0.01V
2) BATT terminal
: DC 3.80V± 0.01V
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
DVM
TX-RX LV
(B/2)
Power meter TX-RX ANT
TX-RX VR3
f. counter (B/2)
(B/2)
Measurement
Test-
Unit
Terminal
Unit
equipment
Power meter TX-RX ANT
TX-RX VR4
Ammeter (B/2)
(B/2)
Power meter TX-RX ANT
Linear
(B/2)
detector
TX-RX MIC
(A/2)
AG
AF V.M
Linear
TX-RX ANT
detector
(B/2)
Measurement
Test-
Unit
Terminal
Unit
equipment
SSG
TX-RX ANT
TX-RX L36
(B/2)
(B/2)
Oscilloscope TX-RX SP
DVM
(A/2)
SSG
TX-RX ANT
(B/2)
Distortion TX-RX SP
meter
(A/2)
Oscilloscope
AF V.M
SSG
TX-RX ANT
(B/2)
AF V.M
(A/2)
DC power TX-RX VCC (+)
supply
(A/2)
GND (–)
DVM
UBZ-LJ8
Adjustment
Parts
Method
Check
0.7~2.7V
± 100Hz
446.04375MHz
Adjustment
Parts
Method
± 10mW
500mW
Current check
500mA or less
± 0.05kHz
VR1
2.0kHz
According to the
larger +, –.
Check
1.2~1.9kHz
[UP],
Write the new
0.35kHz± 0.05kHz
[DOWN] adjustment value
by pushing [PTT].
Check
0.25~0.40kHz
Adjustment
Parts
Method
Maximum AC level
0.9V or more
(peak to peak) using
oscilloscope
Check
SINAD : 20dB or more
Check
Squelch open
Squelch close
LCD check
Specifications/Remarks
Specifications/Remarks
Specifications/Remarks
or
light on
or
lignt on
19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents