EGi Millennium 1201 User Manual

Control console, audio processor

Advertisement

ESPAÑOL • ENGLISH
ESPAÑOL • ENGLISH
Manual
del usuario
User's manual
EG
i
Electroacústica
General
Ibérica, S.A.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Millennium 1201 and is the answer not in the manual?

Questions and answers

Summary of Contents for EGi Millennium 1201

  • Page 1 Manual del usuario User’s manual Electroacústica General ESPAÑOL • ENGLISH ESPAÑOL • ENGLISH Ibérica, S.A.
  • Page 2 Index 1201 - Control console _________________________________________________ 28 - 29 1301 - Audio processor _____________________________________________________ 3 0 1202 - Control console _____________________________________________________ 3 1 Basic operation ______________________________________________________ 32 - 34 Access restrictions ________________________________________________________ 3 4 Advanced functions ___________________________________________________ 35 - 38...
  • Page 3: Control Console

    Control console 1201 1201 Once the Console is turned ON, a menu will appear indicating the control keys for the zones (zone 1 , zone , zone 3 ) and the dial position of the FM radio of the processor (only if the processor includes a FM radio).
  • Page 4: Control Console

    When it is pressed, the symbol < will appear to indicate that the zone 2 has been selected. Push button for selection of zone 1 When it is pressed, the symbol < will appear to indicate that the zone 1 has been selected. Location of gooseneck microphone Location for the microphone with gooseneck, only in 1201.11 version.
  • Page 5: Audio Processor 3

    Version 1301.1 incorporates a FM tuner and a dual RCA input for external musical sources ON/OFF switch for the installation Input for 1201 module Phone type input RJ45 for the connection of the 1201 control console. There is also the possibility of connecting it internally. Antenna input Coaxial input for FM antenna.
  • Page 6 Control console 1202 1202 The control console 1202 is provided with a 4-line LCD display and a keyboard which allow the user to control and program all the possible functions. The operation language can be selected between a total of six at the function menus. The console enables also the control of up to four radio tuners installed in the 1316 audio processor.
  • Page 7 1202 Control console 1202. Basic operation Turning the system "On" and "Off" Turning a zone "On" and "Off" Changing the audio channel in a zone Altering the volume level of a zone If three groups -for instance- have been If three groups -for instance- have been If three groups -for instance- have been previously created: previously created:...
  • Page 8 1202 Control console 1202. Basic operation Turning a Group of zones “On” and Changing an audio channel from Tuning of a channel with internal radio Making a call to zones which are not “Off” in a specific channel external (AUX) music source to in “private”...
  • Page 9 1202 1202 Control console 1202. Basic operation Control console 1202. Access restrictions Making a call when any of the targeted Enabling and disabling the general Entering the general access password zones is in “private” mode access password If the general access password is acti- If three groups -for instance- have been If three groups -for instance- have been ve, whenever we want to access to the...
  • Page 10 If the general access password is active the system will require us to introduce it every time we 1202 Control console 1202. Advanced functions try to operate one of the advanced functions (see point 2 of “access restrictions”). Giving a number to each zone Labelling the zones with names Creating a group and giving it a number HERE...
  • Page 11 If the general access password is active the system will require us to introduce it every time we 1202 Control console 1202. Advanced functions try to operate one of the advanced functions (see point 2 of “access restrictions”). Labelling groups with names Assigning a zone to a group Changing the order of appearance of Erasing a group...
  • Page 12 If the general access password is active the system will require us to introduce it every time we 1202 Control console 1202. Advanced functions try to operate one of the advanced functions (see point 2 of “access restrictions”). Changing the Public Address volume Enabling and disabling the “private”...
  • Page 13 If the general access password is active the system will require us to introduce it every time we 1202 Control console 1202. Advanced functions try to operate one of the advanced functions (see point 2 of “access restrictions”). Checking the software versions Initialising the system If three groups -for instance- have been It is recommended to proceed with this...
  • Page 14 If the general access password is active the system will require us to 1202 Control console 1202. Operation of the module for sending messages over the telephone introduce it every time we try to operate this module (see point 2 of “access restrictions”).
  • Page 15 If the general access password is active the system will require us to 1202 Control console 1202. Operation of the pre-recorded message player introduce it every time we try to operate this module (see point 2 of “access restrictions”). Selecting the destination of a message Broadcasting a message at a definite time Broadcasting a message as a reaction Respecting...
  • Page 16: Control Console 3

    If the general access password is active the system will require us to 1202 Control console 1202. Operation of the pre-recorded message player introduce it every time we try to operate this module (see point 2 of “access restrictions”). Changing the volume level of a Replay of a message Monitoring a message REPEAT...
  • Page 17: Access Restrictions 3

    If the general access password is active the system will require us to 1202 Control console 1202. Operation of the pre-recorded message player introduce it every time we try to operate this module (see point 2 of “access restrictions”). Recording a message Erasing a message Time setting MORE...
  • Page 18: Central Rack Modules 4

    Central Rack Modules 1315 Power Supply Unit. Once connected to 230 V~, it supplies 15 Vdc for the other devices in the central rack and for the general line as well. Central Processing Unit 1316. It is the main device that controls the different elements of the system. It communicates with the system devices, monitoring the control parameters.
  • Page 19: Channel 5 W Control Unit 4

    2-Channel, 5 W Control unit 1204 1204 Push button ON/OFF On press turns on and the next press turns off the sound system in that zone. NOTE: The control unit can be turned on at a moderate volume level by pressing while the unit is still OFF.
  • Page 20: Pre-Amplified Xlr Microphone Base 4

    Pre-amplified XLR microphone base 1105 1105 Professional XLR microphone socket Microphone type selector This switch enables the user to select which type of microphone will be connected to the XLR socket: dynamic, electret without power supply or electret with phantom power supply. Pilot lamp ON It keeps on lighted while the device is working correctly, no matter if there is a microphone connected or not.
  • Page 21: Auxiliary Input 4

    It lights when the RCA connectors are receiving an audio signal from an external music source which is over the minimum sensitivity threshold. Inlet for console Inlet type RJ45 for the connection of control consoles 1201 or 1202. Inlet for external audio source RCA inlet for the connection of external audio sources.
  • Page 22: Channel 1 W Control Unit 4

    4-Channel, 1 W Control unit 1205 1205 ON/OFF push button One press turns on and the next press turns off the sound system in that zone. NOTE: The control unit can be turned on at a moderate volume level by pressing while the unit is still OFF.
  • Page 23: Channel 2 W Control Unit 4

    4-Channel, 2 W Control unit 1207 1207 Push button ON/OFF One press turns on and the next press turns off the sound system in that zone. The current status will be showed by the light of a red lamp. Volume regulator To turn up or down the volume level of the control unit.
  • Page 24: Adapting Musical Sources To The Audio Processors 4

    Adapting musical sources to the audio processors The audio processors allow nearly every type of audio source to be connected to them, like cassette players, radio tuners, CD players, HI-FI systems, compact HI-FI, satellite TV, PC soundblaster, etc. For a correct operation of the set, you should go through the following steps: Ask your installer to connect the musical device that you want to the audio processor.
  • Page 25: Guarantee 5

    Garantía Guarantee garantiza sus fabricados electrónicos y electroacústicos contra cualquier defecto de fabricación guarantees its electronic and electroacoustic products against any manufacturing defect that que afecte a su funcionamiento durante 24 meses a partir de la fecha de su producción (indicada affects its operation for 24 months from the production date (indicated in every manufacture), taking en cada fabricado), comprometiéndose a reparar o reponer los módulos defectuosos cuyo fallo, siempre the commitment of repairing or replacing the faulty modules which failure, always to the discretion of...
  • Page 26 Fecha de instalación / Installation date Empresa instaladora / Installer Electroacústica General Ibérica, S.A. Avda. Almozara, 79 50003 ZARAGOZA (Spain) Tel. 976 40 53 53 Export phone +34 976 40 53 56 Fax +34 976 40 53 54 e-mail: info@egiaudio.com http://www.egiaudio.com...

Table of Contents