Section 5: Installing The Gas Line; Fuel Conversion; Gas Pressure; Gas Connection - Montigo L38DF-ST Indoor Installation & Maintenance Manual

L-series residential fireplace
Table of Contents

Advertisement

Section 5: Installing the Gas Line

Section 5-1:

FUEL CONVERSION

Verify that your fireplace is compatible with your available gas
type. (Natural Gas or Propane shown by "N" or "L" in your
model number
If gas type is not compatible, contact your local Montigo repre-
sentative to purchase a conversion kit.
Conversion kits must be installed by a qualified service techni-
cian.
Section 5-2:

GAS PRESSURE

Optimum appliance performance requires proper input pres-
sures.
Gas line sizing requirements will be determined in ANSI
Z221.3 National Fuel Gas Code in the USA and CAN/CGA
B149 in Canada.
Pressure requirements are:
Gas Pressure
Minimum inlet pressure
Manifold pressure
The manifold outlet pressure is set from the factory to the
appropriate pressure but should be verified.
To check pressures, control valves have a provision to re-
move a 1/8" N.PT. plug to be fitted with a hose barb.
Montigo requires a service shut off valve be located in an ac-
cessible location to isolate the gas supply.
Only install gas shut-off valves approved for use by the state,
province, or other governing body in which the fireplace is
being installed.
Section 5-3:

GAS CONNECTION

See Figure 19 for location of gas line access.
Flexible gas connectors must not exceed 3 feet in length, un-
less allowable within local regulations.
Connect incoming gas line to the 1/2"or 3/8" gas inlet port.
Purge all air out of gas line.
Check appliance connection, valve and valve train under
normal operating pressure with a commercially available leak
check solution.
DO NOT USE A FLAME OF ANY KIND TO TEST FOR
LEAKS.
XG0810 - 070714
Installation
Natural Gas
Propane
5.5in. w.c.
11in. w.c.
3.5in. w.c.
10in. w.c.
1 3/4"
2 3/8"
7"
Figure 19. Gas line access.
Note:
After gas line is connected, each appliance connection,
valve and valve train must be checked while under normal
operating pressure with either a liquid solution, or leak
detection device, to locate any source of leak. Tighten any
areas where bubbling appears or leak is detected until
bubbling stops completely or leak is no longer detected.
DO NOT use a flame of any kind to test for leaks.
NOTICE
When pressure testing the fireplace, Gas line, and input system follow the appropriate
local codes or your area. DO NOT connect the fireplace to pressures in excess of
1/2lb. This will damage the gas control valve.
L38DF-ST* Indoor Gas Fireplace
1 3/4"
Page 19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L38df-stnL38df-stlL38df-stn-fL38fdf-stl-f

Table of Contents