Indoor Fan Speed Control; Airflow Direction Control - Panasonic CS-A12CTP Service Manual

Room air conditioner
Hide thumbs Also See for CS-A12CTP:
Table of Contents

Advertisement

7.9.

Indoor Fan Speed Control

Auto Fan Speed Control
When set to Auto Fan Speed, the fan speed is shifted automatically between Stop to SHi depend on each operation as shown
below.
Manual Fan Speed Control
Basic fan speed adjustment (3 settings, from Lo to Hi) can be carried out by using the Fan Speed selection button at the remote
control.

7.10. Airflow direction control

1. Manual operation
When the airflow direction adjustment button of the remote
control is pressed, the louver moves up/down in the
movable range shown in the diagram at right, and can be
stopped at the required position.
Only the up/down louvers are adjustable from the remote
control.
2. Automatic airflow direction
a. For cooling and soft dry
The up/down louver swings within the movable range.
b. For heating
As shown in the diagram at left, the blow out angle
changes according to the blow out temperature.
* Angle of the left/right louver is manually adjusted.
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5