Indoor Unit - Panasonic CS-A12CTP Service Manual

Room air conditioner
Hide thumbs Also See for CS-A12CTP:
Table of Contents

Advertisement

Indoor Unit

AUTO
OFF / ON
Automatic Operation Button
• Press for < 5s to operate Automatic
operation mode.
(Used when the remote control cannot be used.)
• Press continuously for 5s or < 10s to
operate Test Run/Pump down. "Beep"
sound will be heard at the 5th second.
(Used when test running or servicing.)
• Press continuously for 10s and above to
omit or resume the remote control signal
receiving sound. "Beep, beep" sound will
be heard at the 10th second.
Operation Indication Lamps (LED)
(Green) ......... Lights up in operation,
POWER
(Orange) ......... Lights up in Sleep Mode
SLEEP
(Orange) ....... Lights up in Timer
TIMER
(Orange) ... Lights up in Auto Air
AIR SWING
Operation Mode
• Heating, Cooling, Soft Dry and Automatic
Mode.
Random Auto Restart Control
• Operation is restarted randomly after
power failure at previous setting mode.
Anti-Freezing Control
• Anti-Freezing control for indoor heat
exchanger. (Cooling and Soft Dry)
Sleep Mode Auto Control
• Indoor Fan operates refer to Indoor Fan
Speed.
• Operation stops after 8 hours.
blinks in Automatic
Operation Mode judging,
deice operation and
hotstart.
Operation.
Setting.
Swing Mode Operation.
3
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5
Indoor Fan Speed Control
• High, Medium and Low.
• Automatic Fan Speed Mode
Heating : Fan speed varies from Me →
SSLo in accordance with
indoor heat exchanger.
Cooling : Fan rotates at Hi, Me and
SLo speed.
Soft Dry : Fan rotates at Lo- speed.
Airflow Direction Control
• Automatic air swing and manual adjusted
by remote control for vertical airflow.
• Manually adjusted by hand for horizontal
airflow.
Time Delay Safety Control
• Restarting is inhibited for appro. 3 minutes.
7 Minutes Time Save Control
• Cooling Operation only.
30 Minutes Time Save Control
• Heating Operation only.
Hot-Start Control
• At Heating Operation the indoor fan will
operate at SLo speed when indoor heat
exchanger temperature reaches 30°C.
Anti Cold Draft Control
• The indoor fan operates at SSLo when the
indoor heat exchanger temperature is low.
(During Heating mode thermal off)
Anti-Dew Formation Control
• Anti-Dew Formation Control for indoor unit
discharge area.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu-a12ctp5Cs-a24ctpCu-a24ctp5Cs-a18ctpCu-a18ctp5

Table of Contents