MC-GG773-00 1.2. PICTORIAL DIAGRAM NOTE: For general servicing, it is necessary to eliminate pinching of any wire during reassembly. After servicing any electrical component or electrical enclosure, the unit should be reassembled and checked for dielectric breakdown or current leakage.
MC-GG773-00 2.4. Packing Materials 2.4.1. Exploded View 2.4.2. Parts List (Packing Materials) Ref. No. Part No. Part Name & Description Quantity Remarks AC61ZDEKZ000 Packing Assembly Includes 1 and items a thru g...
MC-GG773-00 3 REPLACEMENT INSTRUCTIONS 3.1. Lower Plate Replacement 3.1.1. Removal 1. Before servicing any parts, disconnect vacuum from electrical outlet. 2. Place paper under nozzle whenever lower plate is removed to protect floor. 3. Place handle in upright position and turn vacuum over to expose lower plate.
Pull the agitator shaft, opposite end cap and agitator 3.4.2. Installation holder out of the agitator tube. 1. Loop new belt (Panasonic Type UB8 only) around motor shaft and agitator pulley; see illustration for correct belt routing. 2. Reinstall agitator back into nozzle housing grooves.
MC-GG773-00 3.5. Power Cord Replacement 3.6. Switch ON-OFF Replacement 3.5.1. Removal 3.6.1. Removal 1. Remove the switch cover and dust cover to expose the 1. Remove the switch cover expose the electrical connections electrical connections of the power cord. of the switch.
MC-GG773-00 assembly to the nozzle housing. assembly. 4. Remove two air outlet packing and two screws from the motor assembly to open. 5. Remove noise suppressor, motor cap, and motor flange. Save these items to place them on the new motor.