<Note on Reassembling>
(1) Attach the LITHIUM-ION BATTERY in the direction shown in the figure below.
(2) Attach the MAIN PCB as shown in the figure below.
Note on Reassembling (1)
Note on Reassembling (2)
FLASH FPC CN501
CN1001
Disengage.
Insert.
CCD FPC
Disengage.
Disengage.
BATTERY FPC CN702
1. Disengage the FLASH FPC, OPTICAL
UNIT FPC, CCD FPC and BATTERY
FPC, and insert the CN1001 section
into the MAIN PCB. Position with
respect to the boss and the rib and
attach the MAIN PCB.
LITHIUM-ION BATTERY
OPTICAL UNIT FPC
Disengage.
Boss
Rib
MAIN FPC
2. Insert the CCD FPC into the CN2001 with both hands.
3. Using the pin for its center hole, insert the OPTICAL
UNIT FPC. (For preventing the elements on both
ends from being damaged)
4. Fix the screw 1 and 2 in this order.
(+)
(−)
2
CN2001
CCD FPC
4
1
Elements
Pin
3
OPTICAL UNIT FPC
21
4
2
Elements
CN3001