<Note on Reassembling>
(1) Attach the DOUBLE-SIDED TAPE (0.06 × 4 × 9mm) and LCD FPC at the respective positions shown in the figure
below. Attach the LCD UNIT as shown in the figure below.
Note on
Supply attachment position
Reassembling (1)
Attach the double-sided tape
(0.06 × 4 × 9 mm) within the
marking-off line.
1. Insert to CN502.
Dowel
2. Insert Claw B.
Claw B
Insert.
Attachment
reference
LCD FPC
Attachment reference
Claw A
Dowel
Insert.
CN502
3. Holding the screw hole section,
push in the LCD UNIT to
engage with the dowel and the
claw A.
8.0mm±1.0
3.
3. Push in.
Claw A
4.
Insert to CN4001.
13
Holding the screw
hole section.
LCD FPC
CN4001
Insert.
LCD FPC
LCD UNIT

Hide quick links: