4. Indoor unit installation
Hook the indoor unit onto the upper portion of the
installation plate.(Engage the two hooks of the rear
top of the indoor unit with the upper edge of the
installation plate.) Ensure that the hooks are properly
seated on the installation plate by moving it left and
right.
Press the lower left and right sides of the unit against
the installation plate until the hooks engage into their
slots(clicking sound).
Connecting the piping to the indoor unit and drain
hose to drain pipe.
1. Align the center of the pipes and sufficiently tighten
the flare nut by hand.
2. Tighten the flare nut with a wrench.
Outside diameter
mm
inch
Ø6.35
1/4
Ø9.52
3/8
Ø12.7
1/2
Ø15.88
5/8
3. Mount the clamp on the boss with a type "B"
screw.(optional)
4. When extending the drain hose at the indoor unit,
install the drain pipe.
Wrap the insulation material around the connecting
portion.
1. Overlap the connection pipe insulation material and
the indoor unit pipe insulation material. Bind them
together with vinyl tape so that there may be no gap.
2. Wrap the area which accommodates the rear piping
housing section with vinyl tape.
3. Bundle the piping and drain hose together by wrap-
ping them with vinyl tape for enough to cover where
they fit into the rear piping housing section.
Torque
kg . m
1.8
4.2
5.5
6.6
Indoor unit tubing
Flare nut
Open-end wrench (fixed)
Wrench
Indoor unit tubing
Type "B" screw
Clamp
Boss
Drain pipe
Indoor unit drain hose
Vinyl tape(narrow)
Adhesive
Plastic bands Insulation material
Connection pipe
Wrap with vinyl tape
Vinyl tape (wide)
Connecting cable
Vinyl tape(narrow)
Wrap with vinyl tape
Pipe
Vinyl tape(wide)
Drain hose
Installation
Connecting
cable
Drain hose
Pipes
Flare nut
Connection pipe
Drain hose
Indoor unit pipe
Pipe
Service Manual 19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents