Installation
Fixing Installation Plate
The wall you select should be strong and solid
enough to prevent vibration
1. Mount the installation plate on the wall with
type "A" screws. If mounting the unit on a concrete
wall, use anchor bolts.
• Mount the installation plate horizontally by aligning
the centerline using a level.
2. Measure the wall and mark the centerline. It is also
important to use caution concerning the location of
the installation plate-routing of the wiring to power
outlets is through the walls typically. Drilling the
hole through the wall for piping connections must
be done safely.
Type 1.
CHASSIS
(Grade)
A
S4
73
S5
121
Type 2.
CHASSIS
(Grade)
A
S4
50
SE
65
S5
95
Drill a Hole in the Wall
• Drill the piping hole with a ø70mm hole core drill.
Drill the piping hole at either the right or the left with
the hole slightly slanted to the outdoor side.
16 Room Air Conditioner
Distance (mm)
B
C
D
55
82
55
62
258
62
Distance (mm)
B
C
D
105
59
105
110
85
110
122
235
122
Installation Plate
Chassis
Hook
Type "A" screw
Type 1.
Installation plate
D
C
Ø70mm
Left rear piping
Type 2.
Installation plate
D
C
Ø70mm
Left rear piping
WALL
Indoor
B
A
Ø70mm
Right rear piping
B
A
Ø70mm
Right rear piping
Outdoor