Trigger operation and timing chart
1. Normal mode
The exposure and the image output are repeated at the set shutter speed.
When the multi shutter speed is set, exposure time (Shutter time) increases every one frame,
and one cycle's worth of an image is output repeatedly.
Shutter time
FLASH OUT
Data output
FVAL
One horizontal period and branking period (*1) are different because of the setting of the configuration and the clock
frequency.
Cameralink output setting
Base configuration 40MHz
Base configuration 80MHz
Medium configuration 40MHz
Medium configuration 80MHz
Full configuration 40MHz
Full configuration 80MHz
(*2) is 1088H at partial scan OFF, and set value of width at partial scan ON.
Shutter time
(Camera setting value)
(*1)
One horizontal period
1H = 25.800μs
1H = 12.900μs
1H = 12.900μs
1H = 6.450μs
1H = 6.450μs
1H = 3.225μs
(*2)
Branking period (*1)
3.25H
4.5H
4.5H
7H
7H
12H