- To activate the Motion Sensor, press the Learn
button located inside the battery compartment,
or if mounted wave your hand in front of the
Sensor (the red LED indicator will flash inside lens
area in front of the Motion Sensor).

Testing a Sensor or your system

Once all the Sensors have been assigned to Zones
in the Control Center you can now test your system.
1
2
3
Zone
Ensure the Control Center can receive the signal
from the intended location of the Sensor before
permanently mounting a Sensor.
Step 1 - To place Control Center in Test mode
unplug AC adapter and remove batteries.
Step  - Press and hold the 'Mute' button and plug
the AC adapter back into the Control Center. When
all the LED indicators turn on, release the Mute
button. The Control Center is now in Test Mode and
any Sensor can now be tested in any Zone.
Step 2
Select the Zone number
1 2 3 4
4
Armed Power
Input DC 12V
-
Mute
Learn
Arm
Alert
Chime
Off
7
Step 1
Press and hold
the Learn button
for three seconds
Step 3
Release the
Zone button
+
Step 4
To activate the Motion
Sensor press the button
on the inside of the unit.