LG LA090HYV Owner's Manual page 23

Art cool premier wall mounted
Hide thumbs Also See for LA090HYV:
Table of Contents

Advertisement

Table 7: Art Cool Premier Troubleshooting (Continued)
Issue
The air conditioner does not generate warm air.
The air conditioner stops during operation.
Air conditioner is still operating, even after being shut
down.
Mist is discharged from the air outlet of the indoor unit.
Water leaks from the outdoor unit.
Due to our policy of continuous product innovation, some specifications may change without notification.
Cause
• When the heating mode is
started.
• Vane is almost closed and air
flow does not come out.
• Outdoor unit is operating but
no warm air is generating.
Outdoor unit is in defrost mode
at the time.
Outdoor temperature is too low.
The air conditioner is suddenly
turned off.
Power failure has occurred dur-
ing air conditioner operation.
• Auto clean mode is in operation.
• This function removes the rest of
the moisture from the indoor unit.
Cooled air from the indoor unit
can form a mist.
Cooled air from the air condi-
tioner is forming mist.
trOublesHOOtInG
Single Zone Art Cool Premier
Corrective Action
This is normal operation of the unit.
During start up, unit is preparing
warm air.
• In heating mode, ice/frost is built up on the
coils when the outside temperature falls.
• Defrost mode removes a layer of frost from the
coil.
• Wait until this operation is completed. It takes
about 15 minutes.
Heating capacity of the unit may not be suffi-
cient to effectively warm air.
• Check to see if timer function has been set to
turn off at designated time.
• Check timer settings and make adjustments as
needed.
• Auto restart is the default setting and is re-
booting the system.
• If you experience frequent power failures, it
is helpful to verify that system is set to auto
restart so that the unit can re-power quickly.
• Wait until the auto clean mode has finished its
function.
• You may turn this feature off.
If the room temperature is lowered the mist will
stop forming.
• Install drain hose under the base pan.
• Contact the installer of the unit.