IVS 102 Operating Instructions
Q3-30 Single Zone Int. Set Point
Configuration Mode
Par.1-00
Reference/Feedback Unit
Par. 20-12
Minimum Reference/Feedb.
Par.20-13
Maximum Reference/Feedb.
Par.20-14
Par.6-22
Terminal 54 Low Current
Par.6-24
Terminal 54 Low Ref./Feedb. Value
Terminal 54 High Ref./Feedb. Value
Par.6-25
Terminal 54 Filter Time Constant
Par.6-26
Terminal 54 Live Zero
Par.6-27
Live Zero Timeout Time
Par. 6-00
Par.6-01
Live Zero Timeout Function
Par.20-21
Setpoint 1
Par.20-81
PID Normal/ Inverse Control
PID Start Speed [RPM]
Par.20-82
PID Start Speed [Hz]
Par.20-83
PID Proportional Gain
Par.20-93
PID Integral Time
Par.20-94
Par.20-70
Closed Loop Type
Par.20-71
PID Performance
PID Output Change
Par.20-72
Minimum Feedback Level
Par.20-73
Maximum Feedback Level
Par.20-74
PID Autotuning
Par.20-79
Q3-3 Closed Loop Settings
Q3-31 Single Zone Ext. Set Point
Configuration Mode
Par.1-00
Reference/Feedback Unit
Par. 20-12
Minimum Reference/Feedb.
Par.20-13
Maximum Reference/Feedb.
Par.20-14
Par.6-10
Terminal 53 Low Voltage
Par.6-11
Terminal 53 High Voltage
Terminal 53 Low Current
Par.6-12
Terminal 53 High Current
Par.6-13
Terminal 53 Low Ref./Feedb. Value
Par.6-14
Terminal 53 High Ref./Feedb. Value
Par.6-15
Par.6-22
Terminal 54 Low Current
Par.6-24
Terminal 54 Low Ref./Feedb. Value
Par.6-25
Terminal 54 High Ref./Feedb. Value
Terminal 54 Filter Time Constant
Par.6-26
Terminal 54 Live Zero
Par.6-27
Live Zero Timeout Time
Par. 6-00
Live Zero Timeout Function
Par.6-01
Par.20-81
PID Normal/ Inverse Control
Par.20-82
PID Start Speed [RPM]
PID Start Speed [Hz]
Par.20-83
PID Proportional Gain
Par.20-93
PID Integral Time
Par.20-94
Closed Loop Type
Par.20-70
Par.20-71
PID Performance
Par.20-72
PID Output Change
Par.20-73
Minimum Feedback Level
Maximum Feedback Level
Par.20-74
PID Autotuning
Par.20-79
MG.12.E2.02
7 How to Programme the Frequency Con-
Q3-32 Multi Zone / Adv
Configuration Mode
Par.1-00
Reference 1 Source
Par.3-15
Reference 2 Source
Par.3-16
Feedback 1 Source
Par.20-00
Par.20-01
Feedback 1 Conversion
Par.20-02
Feedback 1 Source Unit
Feedback 2 Source
Par.20-03
Feedback 2 Conversion
Par.20-04
Feedback 2 Source Unit
Par. 20-05
Feedback 3 Source
Par. 20-06
Par.20-07
Feedback 3 Conversion
Par. 20-08
Feedback 3 Source Unit
Par. 20-12
Reference/Feedback Unit
Minimum Reference/Feedb.
Par.20-13
Maximum Reference/Feedb.
Par.20-14
Terminal 53 Low Voltage
Par.6-10
Terminal 53 High Voltage
Par.6-11
Par.6-12
Terminal 53 Low Current
Par.6-13
Terminal 53 High Current
Terminal 53 Low Ref./Feedb. Value
Par.6-14
Terminal 53 High Ref./Feedb. Value
Par.6-15
Terminal 53 Filter Time Constant
Par.6-16
Terminal 53 Live Zero
Par.6-17
Par.6-20
Terminal 54 Low Voltage
Par.6-21
Terminal 54 High Voltage
Par.6-22
Terminal 54 Low Current
Terminal 54 High Current
Par.6-23
Terminal 54 Low Ref./Feedb. Value
Par.6-24
Terminal 54 High Ref./Feedb. Value
Par.6-25
Terminal 54 Filter Time Constant
Par.6-26
Par.6-27
Terminal 54 Live Zero
Par. 6-00
Live Zero Timeout Time
Live Zero Timeout Function
Par.6-01
Warning Feedback Low
Par.4-56
Warning Feedback High
Par.4-57
Feedback Function
Par.20-20
Setpoint 1
Par.20-21
Par.20-22
Setpoint 2
Par.20-81
PID Normal/ Inverse Control
PID Start Speed [RPM]
Par.20-82
PID Start Speed [Hz]
Par.20-83
PID Proportional Gain
Par.20-93
PID Integral Time
Par.20-94
Par.20-70
Closed Loop Type
Par.20-71
PID Performance
PID Output Change
Par.20-72
Minimum Feedback Level
Par.20-73
Maximum Feedback Level
Par.20-74
PID Autotuning
Par.20-79
verter
7