IVS-B Drive Quick Guide Quick Guide 1.2 Introduction 1.2.1 Available Literature This quick guide contains the basic information necessary for installing and running the Adjustable frequency drive. 1.2.2 Approvals T T able 1.2 1.2.3 IT Line Power Figure 1.2 IP54 400 V 1–25 hp [0.75–18.5 kW] 1: EMC screw CAUTION IT Line Power...
IVS-B Drive Quick Guide Quick Guide 1.2.5 Disposal Instructions Voltage (V) Power range (HP/kW) Min. waiting time (minutes) 3 x 200 0.34–5 [0.25–3.7] Equipment containing electrical components 3 x 200 7.5–60 [5.5–45] may not be disposed of together with domestic waste.
IVS-B Drive Quick Guide Quick Guide 1.3.3 Dimensions T T able 1.6 Enclosure Power (hp [kW]) Height (in [mm]) Width (in Depth Mounting hole (in Max. [mm]) [mm]) Weigh [mm]) Frame IP Class 3 x 200– 3 x 380– "A incl 240 V 480 V 525–...
Page 9
IVS-B Drive Quick Guide Quick Guide E E nclosure Power (hp [kW]) Height (in [mm]) Width (in Depth Mounting hole (in Max. [mm]) [mm]) Weigh [mm]) IP20 15–20 15.71 16.5 [419] 14.96 5.51 9.76 0.47 0.27 26.5 hp [11– [399] [380] [165] [140]...
IVS-B Drive Quick Guide Quick Guide 1.3.4 Electrical Installation in General All cabling must comply with national and local regulations on cable cross-sections and ambient temperature. Copper conductors required, (167° F [75 C]) recommended. P P ower (HP [kW]) Torque (Nm) Frame IP class 3 x 200–240 V...
IVS-B Drive Quick Guide Quick Guide 1.3.5 Connecting to Line Power and Motor The Adjustable frequency drive is designed to operate all standard three-phased asynchronous motors. For maximum cross-section on wires, please see section 1.6 General Specifications. • • Use a shielded/armored motor cable to comply with EMC emission specifications, and connect this cable to both the decoupling plate and the motor metal.
Page 12
IVS-B Drive Quick Guide Quick Guide H6 Frame H7 Frame IP20 380–480 V 40–60 hp [30–45 kW] IP20 380–480 V 75–100 hp [55–75 kW] IP20 200–240 V 20–25 hp [15–18.5 kW] IP20 200–240 V 30–40 hp [22–30 kW] IP20 525–600 V 30–40 hp [22–30 kW| IP20 525–600 V 60–75 hp [45–55 kW] F F igure 1.4 Figure 1.5...
Page 13
IVS-B Drive Quick Guide Quick Guide H8 Frame H9 Frame IP20 380-480 V 125 hp [90 kW] IP20 600 V 3–10 hp [2.2–7.5 kW] IP20 200–240 V 50–60 hp [37–45 kW] IP20 525–600 V 100–125 hp [75–90 kW] F F igure 1.6 Line Relays Ground...
Page 14
IVS-B Drive Quick Guide Quick Guide MOTOR Figure 1.11 Figure 1.9 H10 Frame IP20 600 V 15–20 hp [11–15 kW] Figure 1.10 Figure 1.12 1-10...
Page 15
IVS-B Drive Quick Guide Quick Guide I2 Frame I3 Frame IP54 380–480 V 1–5 hp [0.75–4.0 kW] IP54 380–480 V 75–100 hp [5.5–7.5 kW] Figure 1.13 Figure 1.14 RS 485 RS 485 Line in Line in Ground Ground Wire clamps Wire clamps Motor Motor...
Page 16
IVS-B Drive Quick Guide Quick Guide IP54 I2-I3 frame F F igure 1.15 I6 Frame Figure 1.17 IP54 380-480 V 30–50 hp [22–37 kW] Figure 1.16 Figure 1.18 I7, I8 Frame IP54 380–480 V 60–75 hp [45–55 kW] IP54 380–480 V 100–125 hp [75–90 kW] 1-12...
(symmetrical), 480 V maximum. Non UL compliance If UL/cUL is not to be complied with, Armstrong recommends using the fuses mentioned in Table 1.18, which will ensure compliance with IEC 61800-5-1: In case of malfunction, not following the fuse recommen- dation may result in damage to the Adjustable frequency drive.
Page 18
IVS-B Drive Quick Guide Quick Guide Circuit Breaker Fuse Non-UL Non-UL Bussman Bussman Bussman Bussman Max fuse Power HP [kW] Type RK5 Type RK1 Type J Type T Type G 3 x 200–240 V IP20 0.34 [0.25] FRS-R-10 KTN-R10 JKS-10 JIN-10 0.5 [0.37] FRS-R-10...
IVS-B Drive Quick Guide Quick Guide Circuit Breaker Fuse Non-UL Non-UL Bussman Bussman Bussman Bussman Max fuse Power HP [kW] Type RK5 Type RK1 Type J Type T Type G 3 x 525–600 V IP20 KTS-R20 4 [3] KTS-R20 KTS-R20 10 [7.5] KTS-R20 KTS-R30...
Page 20
IVS-B Drive Quick Guide Quick Guide Panel PLC etc. Output con- tactor, etc. Grounding rail Cable insula- tion stripped Min. 0.0248 in [16 mm Equalizing cable All cable entries in one side of panel Control cables Motor cable Min. 7.9 in [200 mm] between control Line power supply cable, line cable...
IVS-B Drive Quick Guide Quick Guide 1.3.8 Control Terminals IP54 400 V 1–10 hp [0.75–7.5 kW] IP20 200–240 V 0.34–15 hp [0.25–11 kW] and IP20 380–480 V 0.5–30 hp [0.37–22 kW]: Figure 1.21 Location of Control Terminals Place a screwdriver behind the terminal cover to activate snap.
IVS-B Drive Quick Guide Quick Guide 1.3.9 Electrical Overview 3 Phase power input Motor UDC- Not present on all power sizes UDC+ 50 (+10V OUT) relay2 +10Vdc 0-10Vdc- 240Vac 2A 53 (A IN) 0/4-20 mA 54 (A IN) 0-10Vdc- 0/4-20 mA 55 (COM A IN/OUT) relay1 42 0/4-20mA A OUT / DIG OUT...
IVS-B Drive Quick Guide Quick k Guide 1.4 Programming Certain information can be read from the display. Parameter number and name. 1.4.1 Programming with the Local Control Panel (LCP) Parameter value. Set-up number shows the active set-up and the edit set- up.
IVS-B Drive Quick Guide Quick Guide A A t power-up At the first power-up, the user is asked to choose the preferred language. Once selected, this screen will never be shown again in the following power-ups, but the language can still be changed in 0-01 Language. Select Language ] English Set-up 1...
Page 25
IVS-B Drive Quick Guide Quick k Guide ... the HVAC IVS-B Wizard starts Select Regional Settings At power up the user is Power kW/50 Hz asked to choose the Setup 1 prefered laguage. Grid Type 200-240V/50Hz/Delta Setup 1 Select language [1] English Select Motor Type Setup 1...
Page 26
IVS-B Drive Quick Guide Quick Guide T T he IVS-B Start-up Wizard for Open-loop Applications No & Name Range Default Function 0-03 Regional Settings [0] International [1] US 0-06 Grid Type [0] 200–240 V/50 Hz/IT grid Size related Select operating mode for restart upon [1] 200–240 V/50 Hz/Delta reconnection of the drive to AC line voltage after [2] 200–240 V/50 Hz...
Page 27
IVS-B Drive Quick Guide Quick Guide N N o & Name Range Default Function 6-13 Terminal 53 High 0-20 mA Enter the current that corresponds to the high Current reference value. 3-02 Minimum Reference -4,999–4,999 The minimum reference is the lowest value obtainable by summing all references.
Page 28
IVS-B Drive Quick Guide Quick Guide C C losed-loop Set-up Wizard 0-03 Regional Settings International 0-06 Grid Type [200-240 V/50 Hz] Asynchronous Motor 0-01 Configuration Mode Open Loop 1-20 Motor Power 1.10 1-22 Motor Voltage 1-23 Motor frequency 1-24 Motor current 4.66 1-25 Motor nominal speed 1420...
Page 29
IVS-B Drive Quick Guide Quick Guide C C losed-loop Set-up Wizard No & Name Range Default Function 0-03 Regional Settings [0] International [1] US 0-06 Grid Type [0]-[[132] Please see Size selected Select operating mode for restart upon reconnection of the start-up wizard for open- Adjustable frequency drive to AC line voltage after power-down loop application...
Page 30
IVS-B Drive Quick Guide Quick Guide M M otor Set-up The Quick Menu Motor Set-up guides you through the No & Name Range Default Function needed motor parameters. 1-73 Flying [0] Disabled Select Enable to Start [1] Enabled enable the No &...
Page 31
IVS-B Drive Quick Guide Quick Guide 1.5.1 Parameter Overview P P arameter Overview 0-** Operation / Display 0-11 Programming Set-up 0.00–1,000,000.0, * 0.00 [7] 0.75 kW–1.00 HP 0-0* Basic Settings [1] Set-up 1 0-32 Custom Readout Max Value [8] 1.10 kW–1.50 HP 0-01 Language [2] Set-up 2 0.00–1,000,000.0, * 100.00...
Page 32
IVS-B Drive Quick Guide Quick Guide P P arameter Overview 1-50 Motor Magnetization at 0–150%, * 50 4-** Limits / Warnings 5-1* Digital Inputs Zero Speed 2-02 DC Braking Time 4-1* Motor Limits 5-10 Terminal 18 Digital Input 0–300, * 100% 0.0–60.0 s, * 10.0 4-10 Motor Speed Direction [0] No operation...
Page 33
IVS-B Drive Quick Guide Quick Guide P P arameter Overview [5] Drive running 0.00–600.00 s, *0.01 s 6-25 Terminal 54 High Ref./Feedb. [65] Comparator 5 [6] Running/no warning 5-42 Off Delay, Relay Value [70] Logic rule 0 [7] Run in range/no warning 0.00–600.00 s, *0.01 s -4,999.000 - 4,999.000, * 50.000 [71] Logic rule 1...
Page 34
IVS-B Drive Quick Guide Quick Guide P P arameter Overview [5] Drive running 8-01 Control Site [0] Digital input 8-81 Bus Error Count [6] Running / no warning *[0] Digital and ctrl.word [1] Bus 0–65536, * 0 [7] Run in range/no warning [1] Digital only [2] Logic AND 8-82 Slave Message Rcvd...
Page 35
IVS-B Drive Quick Guide Quick Guide P P arameter Overview [43] Key Ok 13-42 Logic Rule Boolean 2 14-01 Switching Frequency 14-29 Service Code [44] Key Reset See par. 13-01, *[0] False [0] Ran3 0 –0x7FFFFFFF, * 0 [47] Key Up 13-43 Logic Rule Operator 2 [1] Ran5 14-3* Current Limit Ctrl.
Page 36
IVS-B Drive Quick Guide Quick Guide P P arameter Overview 15-3* Fault Log 16-30 DC Link Voltage 16-91 Alarm Word 2 22-** Appl. functions 15-30 Fault Log: 0–65535, * 0 0–0xFFFFFFFFUL, * 0 22-4* Sleep mode Error Code 0–255, * 0 16-34 Heatsink Temp.
Discharge from output phases to ground. Control Voltage Fault 24 V DC may be overloaded. VDD1 Supply Control voltage low. Please contact your local Armstrong supplier. Calibration Contact your local Armstrong supplier. failed The setting of motor voltage, motor current and motor power is Unom,Inom presumably wrong.
Page 38
(Only on 400 V 40–125 hp [30–90 kW] units). Contact your local New spare Armstrong supplier. part The Adjustable frequency drive has a new type code (Only on 400 V 40–125 hp [30–90 kW] units). Contact your local Armstrong New Typecode supplier. Table 1.32 1-34...
IVS-B Drive Quick Guide Quick Guide 1.7 General Specifications 1.7.1 Line Power Supply 3 x 200–240 V AC A A djustable frequency drive P15K P18 P22K P30 P37K P45 Typical shaft output (kW) 0.25 0.37 0.75 1.5 11.0 15.0 18.5 22.0 30.0 37.0...
IVS-B Drive Quick Guide Quick Guide 1.7.5 EMC Test Results The following test results have been obtained using a system with a Adjustable frequency drive, a shielded control cable, a control box with potentiometer, as well as a motor shielded cable. R R FI Filter Conduct emission.
Page 46
IVS-B Drive Quick Guide Quick Guide R R FI Filter Conduct emission. Maximum shielded cable length (m) Radiated emission Type 1–25 [0.75– 18.5 kW] 3 x 380–480 V IP54 30–125 hp [22–90 kW] 3 x 380–480 V IP54 Table 1.39 Protection and features •...
Page 47
IVS-B Drive Quick Guide Quick Guide Minimum cross-section to control terminals 0.05 mm /30 AWG *See tables for line power supply for more information Digital inputs: Programmable digital inputs Terminal number 18, 19, 27, 29 Logic PNP or NPN Voltage level 0-24 V DC Voltage level, logic '0' PNP <...
Page 48
IVS-B Drive Quick Guide Quick Guide Relay output Programmable relay output Relay 01 and 02 01-03 (NC), 01-02 (NO), 04-06 (NC), 04-05 (NO) Max. terminal load (AC-1) on 01-02/04-05 (NO) (Resistive load) 250 V AC, 3A Max. terminal load (AC-15) on 01-02/04-05 (NO) (Inductive load @ cos 0.4) 250 V AC, 0.2 A Max.
The cooling capability of air is decreased at low air pressure. For altitudes above 6,600 feet [2,000 m], please contact Armstrong regarding PELV. Below 3,281 ft [1,000 m] altitude no de-rating is necessary, but above 3,281 ft [1,000 m] the ambient temperature or the maximum output current should be decreased.