L
IGHTING AND
W
: I
ARNING
F YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY
,
DAMAGE
PERSONAL INJURY OR LOSS OF LIFE
A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions
exactly.
B. Before lighting smell all around the appliance area for gas. Be sure to smell next to the floor because some gas
is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

• D
O NOT TRY TO LIGHT ANY APPLIANCE
• D
O NOT TOUCH ANY ELECTRIC SWITCH
• I
MMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR
• I
F YOU CANNOT REACH YOUR GAS SUPPLIER
C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn
by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or
explosion.
D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to
inspect the appliance and to replace any part of the control system and any gas control which has been under
water.

LIGHTING INSTRUCTIONS

READ THE PRECEDING SAFETY INFORMATION BEFORE LIGHTI
INFORMATION ABOVE ON THIS PAGE.
to off. As you turn the knob between Pilot
to off. As you turn the knob between Pilot and Off you will hear a click. This indicates a safety
has been activated that will prevent you from
Wait until the lockout is deactivated befor
while the lockout feature is activated will dama
out any gas. Then smell for gas, including nea
you don't smell gas, go to the next step.
n the next page. Turn the control knob counte
control knob as you turn it.)
are not directly in front of the heater, but where
olding it down, immediately depress the ignitor
the ignitor at five second intervals for a ma
with a match, on the next page of this manua
o hold the control knob down for a minute an
emain lit.
s not pop up when released, stop and immediately and call
lit after several tries, turn the gas control knob cl
lier.
ng steadily, slowly turn the control knob coun
e burners cycle off before the room has reach
of time the burners burn before cycling off
e control knob may be turned to Pilot or OFF.
TO THE APPLIANCE
e
to OFF. The knob will click between pilot and OFF.
to OFF. The knob will click betwee
- Turn the control knob clockwise
and turn the shutoff valve
and turn the shutoff valve off. (See Figures 2 & 3)
16
53D9012. Rev 1 03/03
O
H
PERATING
F
Y
S
OR
OUR
AFETY
.
.
;
DO NOT USE ANY PHONE IN YOUR BUILDING
,
CALL THE FIRE DEPARTMENT
EATER
- R
B
EAD
EFORE
,
A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY
'
. F
S PHONE
to OFF
to OFF
L
IGHTING
.
OLLOW THE GAS SUPPLIER
.
until it stops at the Pilot position.
to "OFF" and call your service
past LO toward HI until the
IGNITOR
BUTTON
(SHOWN IN "OFF" POSITION)
'
.
S INSTRUCTIONS