Monessen Hearth IRVF2T Installation, Operation And Maintanance Manual
Monessen Hearth IRVF2T Installation, Operation And Maintanance Manual

Monessen Hearth IRVF2T Installation, Operation And Maintanance Manual

Infrared unvented room heaters with thermostat control

Advertisement

Quick Links

IRVF2T, IRVF3T,
I
U
NFRARED
T
WITH
HERMOSTAT
I
NSTALLATION
T
HE DESIGN OF THIS HEATER COMPLIES WITH STANDARD
CSA I
CERTIFIED BY
NTERNATIONAL
T
HIS APPLIANCE MAY BE INSTALLED IN AN AFTERMARKET
WHERE NOT PROHIBITED BY LOCAL CODES
T
HIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING LABEL
CONVERTIBLE FOR USE WITH OTHER GASES
WARNING: I
F THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY
CAUSING PROPERTY DAMAGE
D
O NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER
.
APPLIANCE
WHAT TO DO IF YOU SMELL GAS
• D
O NOT TRY TO LIGHT ANY APPLIANCE
• D
O NOT TOUCH ANY ELECTRICAL SWITCH
• I
MMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR
.
INSTRUCTIONS
• I
F YOU CANNOT REACH YOUR GAS SUPPLIER
I
NSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER
T
HIS IS AN UNVENTED GAS
FOR ADEQUATE COMBUSTION AND VENTILATION AIR MUST BE PROVIDED
A
R
IR
EQUIREMENTS
AND
R
NVENTED
OOM
C
ONTROL
, O
PERATION AND
.
.
.
,
PERSONAL INJURY OR LOSS OF LIFE
.
;
-
. I
FIRED HEATER
T USES AIR
SECTION OF THIS MANUAL FOR DETAILS
IRVF5T M
H
EATERS
M
AINTENANCE
Z21.11.2
OF THE
,
PERMANENTLY LOCATED
.
DO NOT USE ANY PHONE IN YOUR BUILDING
'
S PHONE
,
CALL THE FIRE DEPARTMENT
(
)
OXYGEN
FROM THE ROOM IN WHICH IT IS INSTALLED
. R
EFER TO
.
ODELS
A
N
S
MERICAN
ATIONAL
TANDARDS
,
MANUFACTURED
. T
HIS APPLIANCE IS NOT
,
A FIRE OR EXPLOSION MAY RESULT
.
. F
OLLOW THE GAS SUPPLIER
.
,
SERVICE AGENCY OR THE GAS SUPPLIER
C
OMBUSTION AND
M
ANUAL
I
NSTITUTE AS
(
)
,
MOBILE
HOME
'
S
.
. P
ROVISIONS
V
ENTILATION
53D9012. Rev 1 03/03

Advertisement

Table of Contents
loading

Summary of Contents for Monessen Hearth IRVF2T

  • Page 1 IRVF2T, IRVF3T, IRVF5T M ODELS NFRARED NVENTED EATERS WITH HERMOSTAT ONTROL NSTALLATION PERATION AND AINTENANCE ANUAL Z21.11.2 HE DESIGN OF THIS HEATER COMPLIES WITH STANDARD OF THE MERICAN ATIONAL TANDARDS NSTITUTE AS CSA I CERTIFIED BY NTERNATIONAL HIS APPLIANCE MAY BE INSTALLED IN AN AFTERMARKET...
  • Page 2: Table Of Contents

    ABLE OF ONTENTS Your heater has been designed for years of safe, efficient, and trouble-free operation provided the instructions in this manual are followed. To help insure your safety, it is very important that you take time to read this entire manual before installing or operating this heater. Important Information ....................
  • Page 3: Important Information

    EQUIPPED WITH EQUIPPED WITH EQUIPPED WITH HEATER IN HEATER LP GAS NATURAL GAS type for which it was equipped at the factory. IRVF2T 10,000 10,000 IRVF3T 15,000 18,000 Warning: Any change to this heater or its controls can be IRVF5T...
  • Page 4: Parts Diagram And List

    ARTS IAGRAM RIGHT RIGHT SIDE SIDE FRONT FRONT LEFT LEFT SIDE SIDE 53D9012. Rev 1 03/03...
  • Page 5 Model number of your Appliance, Part Name, Part Number, and Quantity of parts needed. D O NOT TAKE A HEATER NEEDING REPAIR OR BELIEVED TO BE DEFECTIVE BACK TO THE SELLER QTY. PER IRVF2T IRVF3T IRVF5T DESCRIPTION HEATER PART NO. PART NO.
  • Page 6: How This Appliance Operates

    PPLIANCE PERATES This heater is to be installed either wall mounted or freestanding Warning: This heater is hot while according to these instructions and must not be enclosed within a in operation. Do not touch. Keep confined space or within a cabinet. It is intended to provide heat directly to the space in which it is located.
  • Page 7: Selectinga Location

    ELECTING OCATION These heaters are shipped from the factory equipped for mounting on a Danger: Do not install this flat wall. A wall-mount template is provided with each heater to aid in heater in any area where locating the heater on a wall. Maintaining at least the minimum spacing gasoline or any combustible or to combustibles as illustrated by Figure 1 is required for safety.
  • Page 8 Standards Institute, none of the heaters described by this manual 10,000 Btu’s per hour in a may be installed in a bathroom and the IRVF2T is the only model bedroom. that may be installed in a bedroom. If an infrared heater is installed in a bedroom, it must be wall mounted.
  • Page 9: Gas Piping And Pressure Requirements

    IPING AND RESSURE EQUIREMENTS All gas piping must be installed to comply with local codes or, in the All gas piping must be installed absence of local codes, with the latest edition of the National Fuel Gas to comply with local codes or, in Code ANSI Z223.1/NFPA 54.
  • Page 10 IPING AND RESSURE EQUIREMENTS CONTROL KNOB IGURE IGNITOR BUTTON FLOOR STAND REQUIRED IF FLOOR STAND REQUIRED IF HEATER IS TO BE INSTALLED HEATER IS TO BE INSTALLED UNION AS A FREESTANDING HEATER. AS A FREESTANDING HEATER. (FLOOR STAND SOLD AS AN ACCESSORY.) (FLOOR STAND SOLD AS AN ACCESSORY.) SHUTOFF VALVE...
  • Page 11: Combustion And Ventilation Air Requirements

    OMBUSTION AND ENTILATION EQUIREMENTS This heater requires fresh air (oxygen) for proper combustion and ventilation. In some cases, but not all, normal air infiltration into a building Warning: If the area in which will supply a sufficient amount of fresh air for proper combustion and this appliance may be operated ventilation.
  • Page 12 OMBUSTION AND ENTILATION EQUIREMENTS Consult your local building inspector or section 5.3 in the latest edition Warning: The ODS (Oxygen of National Fuel Gas Code ANSI Z223.1/NFPA 54 if you have any Depletion Sensor) Pilot safety questions about fresh air requirements for proper combustion and system is not a substitute for ventilation of gas-fired appliances.
  • Page 13: Installation And Adjustment

    A model XAB theromstatically controlled, or model XMB manually controlled, blower may be installed on the IRVF3T and IRVF5T heaters. (IRVF2T models are not designed for use with optional blowers.) These blowers are the only blowers acceptable for use on these heaters. The use of any other blower could adversely and dangerously affect the operation of these heaters.
  • Page 14 NSTALLATION AND DJUSTMENT 4. Mark locator points on wall; remove template and drive wall-mount Danger: Excessive torque anchors through the locator points and into the wall as shown by Figure 5. (twisting) on the inlet fitting of this heater may cause gas leaks at IGURE one or more of the fittings inside FLAT SURFACES OF ANCHOR BLADES...
  • Page 15 7. If the heater is to be equipped with an optional blower, install the blower according to the instructions provided with the blower. (Note: IRVF2T heaters cannot be equipped with a blower.) 8. Locate the two key-hole slots on the back of the heater. Align the large openings of the key-hole slots with the mounting screws in the anchors in the wall.
  • Page 16 NSTALLATION AND DJUSTMENT OUNT AND REESTANDING NSTALLATION " 17. Carefully read the entire " section IGHTING PERATING EATER of this manual, then light the heater’s pilot according to the instructions. The pilot flame should be blue and should appear as "M "...
  • Page 17: Lighting And Operating Heater

    NSTALLATION AND DJUSTMENT 20. Immediately after the burner plaques light, use a soapy water Danger: Do not use candles, solution or a liquid gas leak detector to check all burner tube joints matches or other ignition sources for gas leaks. If any leaks are found, turn the shutoff valve off and when checking for gas leaks.
  • Page 18: What To Do If You Smell Gas

    IGHTING AND PERATING EATER AFETY EFORE IGHTING ARNING F YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.
  • Page 19 IGHTING AND PERATING EATER ALTERNATE METHOD OF LIGHTING THE PILOT WITH A MATCH Follow the steps as if you were going to light the pilot with the push button i Follow the steps as if you were going to light the pilot with the push button ignitor up to the point of pushing down on the control knob to initiate the flow of gas to the pilot.
  • Page 20: Safety Checklist

    AFETY HECKLIST Continued safe operation of this heater requires, but is not limited to, these “Do’s” and “Don’ts”: DO’S: Do make the installation according to local codes or, in the absence of local codes, with latest edition of the National Fuel Gas Code ANSI Z223.1/NFPA 54. Do provide ample fresh air when using heater.
  • Page 21: Maintenance

    AINTENANCE To avoid electrical shock, turn off all electrical power to the heater if service is to be performed on a heater that is equipped with an optional blower. It is necessary to . In even the cleanest homes, lint and dust carried KEEP BURNER AND CONTROL COMPARTMENT CLEAN by air moving through the heater will collect on parts of the heater.
  • Page 22: Troubleshooting

    ROUBLESHOOTING Due to high temperatures, this appliance must be located out of traffic and away from furniture and draperies. Children and adults should be alerted to the hazard of high surface temperature and should be kept away to avoid burns or clothing ignition. Children should be carefully supervised when in the same room with the appliance. Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the appliance.
  • Page 23: Warranty

    IMITATIONS AND XCLUSIONS 1. No one has authority to add to or vary this limited warranty, or to create for Monessen Hearth Systems any other obligation or liability in connection with this heater. 2. Any implied warranty applicable to this heater is limited in duration to the same period of time as this written warranty.
  • Page 24 TTENTION PPLIANCE NSTALLER LEASE RETURN THESE PERATING NSTALLATION NSTRUCTIONS TO THE PPLIANCE FOR ONSUMER 53D9012. R . 1 03/03...

This manual is also suitable for:

Irvf3tIrvf5t

Table of Contents