Monessen Hearth SD30PV Installation & Operating Manual

Monessen Hearth SD30PV Installation & Operating Manual

Sundance vent free gas heater

Advertisement

Installation & Operating Manual
Installation and Appliance Setup - Care and Operation
INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
Call your dealer for questions on Installation, Operation, or Service.
NOTICE: SAVE THESE INSTRUCTIONS
Sundance
Vent Free Gas Heater
®
Models: SD30PV, SD30NV
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
1
Monessen • Sundance VF Installation Manual_R1 • 04/17
!
If the information in this manual is not followed exactly,
a fire or explosion may result causing property damage,
personal injury or loss of life.
—Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
—WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
This appliance may be installed in an aftermarket*
permanently located manufactured (mobile) home where
not prohibited by local codes.
This appliance is only for use with the type of gas indicated
on the rating plate.
This appliance is not convertible for use with other gases
unless a certified kit is used.
*Aftermarket: Completion of sale, not for purpose of resale,
from the manufacturer.
This is an unvented gas-fired heater. It uses air (Oxygen)
from the room in which it is installed. Provisions for adequate
combustion and ventilation air must be provided. Refer to
the Fresh Air Requirements section for further information.
WARNING
3-90-733069

Advertisement

Table of Contents
loading

Summary of Contents for Monessen Hearth SD30PV

  • Page 1 Sundance Vent Free Gas Heater ® —WHAT TO DO IF YOU SMELL GAS Models: SD30PV, SD30NV • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone.
  • Page 2: Table Of Contents

    PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Monessen stove. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Table of Contents 1 Safety &...
  • Page 3: Safety & Operations

    Safety & Operations A. Important Safety Information CARBON MONOXIDE POISONING MAY LEAD TO DEATH! In order to ensure safe and effective installation, this unit must be installed only by a qualified agency, individual, firm, Carbon Monoxide Poisoning: Early signs of carbon corporation or company that is experienced in the installation, monoxide poisoning resemble the flu, with headaches, repair and servicing of this type of appliance and is familiar...
  • Page 4: Stove Dimensions

    B. Stove Dimensions Freestanding Stove Drawing Not to Scale 9" (229 mm) Valve Inlet 26³⁄₄" (680 mm) Valve Inlet 3" (76 mm) 14¹⁄₂" 25¹⁄₂" (368 mm) (648 mm) 15⁵⁄₈" (379 mm) Figure 1 - Sundance freestanding shell dimensions. 5004 UVS27 Freestanding specs 1/02 Monessen •...
  • Page 5: Clearance To Combustibles

    C. Clearance to Combustibles D. Floor Protection Minimum Clearances to Combustible Materials The Sundance must be installed on rigid flooring. If the Maintain clearance, (empty space), between combustible appliance is installed on any combustible surface other than materials and the heater as specified below for the appropriate wood flooring, such as carpet or tile, a metal or wood panel firebox shell being installed.
  • Page 6: Gas Specifications

    E. Gas Specifications G. High Elevations Input ratings are shown in Btu per hour and are certified Gas Specifications without deration from elevations up to 4,500 feet (1,370 m) above sea level. Input Input Shutter Nuisance outages may occur at altitudes above 4,500 feet Model Fuel Control...
  • Page 7: Vent Free Features

    I. Vent Free Features WARNING The Sundance Vent Free gas stove is an unvented gas heating appliance tested and listed to the ANSI standard Z21.11.2, If the area in which the heater may be operated does Latest Edition. This appliance is specifically configured to not meet the required volume for indoor combustion air, burn either Natural Gas or Propane fuel, as indicated on the combustion and ventilation air shall be provided by one...
  • Page 8: Assembly A. Unpack The Stove

    Assembly A. Unpack the Stove 3. Feed the snapstat wire lead up between the inner and outer rear shroud panels and secure the snapstat to the upper Remove the unit from the skid by loosening the bolts located right side of the inner shroud. (Figure 4) in the shipping brackets.
  • Page 9: Install On/Off Switch

    C. Install ON/OFF Switch On/Off Switch Wiring The switch assembly parts are found in the parts bag. 1. Attach switch assembly to left rear side of stove shroud using two screws and existing holes in shroud. (Figure 7) 2. Run wires down back of stove, under bottom of rear shroud to valve.
  • Page 10: Connect The Gas Supply Line

    E. Connect the Gas Supply Line F. Install Log Set Check the Rating Plate attached by a steel cable to the WARNING firebox, to confirm that you have the appropriate firebox for the type of fuel to be used. Failure to position the parts in accordance with this The appliance should have a main gas valve provided in an diagram or, failure to use only parts specifically approved accessible location for turning on or shutting off the gas to...
  • Page 11 3. Install the right log by placing it on the sheet metal bracket Complete the Installation behind the grate with the right end of the log, “the thicker 1. Install the screen frame by sliding the hooks over the end”, touching the grate and the right side the firebox. top front edge of the firebox and resting the bottom Swing the left end of the log “painted end”, backward until on the support brackets.
  • Page 12: Operation

    Operation A. Your First Fire Turn Read these instructions carefully and familiarize yourself Turn clockwise counterclockwise with the burner controls. Locate the pilot assembly, Figure to decrease to increase 14. Follow the lighting instructions on the next page exactly. flame height flame height During the first fire, it is not unusual to smell some odor associated with new logs, paint and metal being heated.
  • Page 13: For Your Safety Read Before Lighting

    E. Lighting & Operating Instructions • If you cannot reach your gas supplier, call the Fire Department FOR YOUR SAFETY READ BEFORE LIGHTING C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn WARNING by hand, do not try to repair it, call a qualified service technician.
  • Page 14: Troubleshooting Guide

    Troubleshooting Guide Follow these procedures in the order presented. WARNING Turn off heater and allow to cool completely before servicing. CONDITION POSSIBLE CAUSE SOLUTION No spark at pilot when Ignitor is A. Ignition Electrode is disconnected Inspect and re-connect, replace or repair operated.
  • Page 15 CONDITION POSSIBLE CAUSE SOLUTION Pilot lights but flame goes out when A. Control Knob not fully depressed or Depress Control Knob fully and hold in Control Knob is released. held in long enough. for a full 30 seconds. B. Gas supply line shut-off valve is not Fully open gas supply line shut-off fully open.
  • Page 16: Maintenance

    Maintenance The following procedures will help ensure that your heater Screen Hooks continues to perform safely and efficiently. A. Cleaning Firebox & Inspection Cleanliness is critical to correct operation of the heater. Glass Latch The log set, burner, valve controls and air circulation areas must all be kept free of dust and unobstructed by debris.
  • Page 17: Reference Materials

    Reference Material A. Service Parts List Sundance Vent Free Gas Heaters - Models 4050, 4051 2a,b 7, 8 16a,b,c,d 14a,b Hearth & Home Technologies reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
  • Page 18: Fan Kit

    Sundance Vent Free Gas Heaters - Models 4050, 4051 Gas Log Assembly 20005005 16a. Orifice Hood #69 (.0292”) - Front - LP 30000513 Log #V40 Rear 20005006 16b. Orifice Hood #54 (.055”) - Front - Nat. 20000130 Log #V42 Left 20005008 16c.
  • Page 19: Warranty

    Hearth & Home Technologies LIMITED LIFETIME WARRANTY Hearth & Home Technologies, on behalf of its hearth brands (”HHT”), extends the following warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer. WARRANTY COVERAGE: HHT warrants to the original owner of the HHT appliance at the site of installation, and to any transferee taking ownership of the appliance at the site of installation within two years following the date of original purchase, that the HHT appliance...
  • Page 20 WARRANTY CONDITIONS: • This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor. A list of HHT authorized dealers is available on the HHT branded websites. • This warranty is only valid while the HHT appliance remains at the site of original installation. •...
  • Page 21 Monessen • Sundance VF Installation Manual_R1 • 04/17 3-90-733069...
  • Page 22 352 Mountain House Road Halifax, PA 17032 Monessen • Sundance VF Installation Manual_R1 • 04/17 3-90-733069...

This manual is also suitable for:

Sd30nv

Table of Contents