Waveforms - Pioneer DEH-34UB/XNUC Service Manual

Pioneer cd rds receiver service manual
Table of Contents

Advertisement

1

10.4 WAVEFORMS

- CD CORE UNIT(S11.6STD)
A
1DSCSNS
5 V/div
3HOME
5 V/div
4LOEJ
5 V/div
12 cm CD Loading operation
Ref.:
GND
B
Mode:
Normal
7SIN
1 V/div
8CIN
500 mV/div
9TIN
500 mV/div
12 cm CD-DA setup operation after loading
C
Ref.:
REFO
Mode:
Normal
dFE
500 mV/div
aFIN
500 mV/div
cTE
500 mV/div
D
9TIN
500 mV/div
CD-DA Play operation
Ref.:
REFO
Mode:
Normal
E
aFIN
500 mV/div
dFE
500 mV/div
Focus Search waveform
Ref.:
REFO
F
Mode:
TEST
48
1
2
Note : 1. The encircled numbers denote measuring points in the circuit diagram.
2. Reference voltage REFO1(1.65 V)
1DSCSNS
500 ms/div
5 V/div
5CLCONT
5 V/div
4LOEJ
5 V/div
6VD1
10 V/div
12 cm CD Loading operation
Ref.:
GND
Mode:
Normal
aFIN
1 s/div
200 mV/div
bRFOK(MONI_2)
2 V/div
7SIN
2 V/div
12 cm CD-DA Source On setup operation
Ref.:
REFO
Mode:
Normal
eMDX
20 ms/div
2 V/div
7SIN
500 mV/div
Spindle waveform during play operation
Ref.:
REFO
Mode:
Normal
cTE
200 ms/div
500 mV/div
fRFAGC
500 mV/div
Track Open waveform
Ref.:
REFO
Mode:
TEST
DEH-34UB/XNUC
2
3
500 ms/div
cTE
500 ms/div
500 mV/div
dFE
500 mV/div
Source On setup operation
Ref.:
REFO
Mode:
Normal
eMDX
50 ms/div
2 V/div
7SIN
500 mV/div
Spindle waveform during play operation
(Wider)
Ref.:
REFO
Mode:
Normal
fRFAGC
2 ms/div
1 V/div
cTE
500 mV/div
9TIN
500 mV/div
100 Track Jump waveform (32 Track Jump x 3)
Ref.:
REFO
Mode:
TEST
3
4
200 ms/div
5 μs/div
500 μs/div
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents